10 | Installation
4.3.1 Water quality
Water quality can have an impact on appliance longevity and
may not be covered under the manufacturer's warranty.
▶ For water analysis data call your local water department, or
if on a well, have well water analyzed periodically.
If water quality exceeds one or more of the values specified
below, Bosch recommends consulting a local water
treatment professional for water softening/conditioning
options.
Description
pH
TDS (total Dissolved
Solids)
Total hardness
Aluminum
Chlorides
Copper
Iron
Manganese
Zinc
4.4

Electrical connections

WARNING:
▶ The unit must be installed by a qualified
electrician.
▶ The unit must be grounded.
▶ Connect the unit to power.
Rated Voltage
Model
(V)
US3
110
277
240
208
240
Table 6
6 720 647 005 (2014/04)
Max. Levels
pH
6.5 - 8.5
mg/l or ppm
mg/l or ppm
(6 grains)
mg/l or ppm
mg/l or ppm
mg/l or ppm
mg/l or ppm
mg/l or ppm
0.05
mg/l or ppm
Rated Current
Recommend
(A)
Wire Size (AWG)
30
10
25
10
30
10
35
8
40
8
Connecting the unit to power
▶ Strip back the insulation on the power wires about
3/8". Any insulation on the ground should be stripped back
about 3/4".
500
▶ Feed the cable through the cover bottom or backplate rear
entry grommets, as appropriate.
100
▶ Connect the cables to the terminal block and ground stud
(Fig. 4 ):
2.0
250
1.0
0.3
5.0
Fig. 4
[1] Ground
[2] Rubber sleeve
▶ Make sure that all the terminal block screws are tightened
securely. Loose connections can cause wires to heat up.
▶ Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut should be
tightened securely.
NOTICE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non grounded
conductors must be provided that is within
sight of the appliance. (REF NEC 422.31)
Cable termination