Adjusting The Flame - COMPANION DC100-09 Instruction Manual

Hide thumbs Also See for DC100-09:
Table of Contents

Advertisement

SAFE INSTALLATION OF
REGULATOR AND HOSE ASSEMBLY
• This appliance must be installed only by a
licensed gas fitter or plumber
• This appliance shall only be used with an
AGA or SAI Global approved LP gas hose
and regulator assembly
• The regulator must be regulated to
2.75kPA output
• The installation of the regulator and hose
assembly must follow Australian Standards
AS5601
• DO NOT use adaptors
• The hose and regulator assembly should
not be assembled beneath the appliance, in
direct sunlight or close to other sources
of heat
• The hose must be free from twists and kinks
• The hose length must not exceed 1800mm
• All connections should be tightened with
a spanner and then leak tested with soapy
water – DO NOT use a naked flame to
check for leaks.
ASSEMBLY OF BURNER HEAD
Correct assembly method
Eliminates the possibility of back fire and
assures the proper functioning of the burner.
Before assembly
After assembly
Wrong assembly method
Will cause backfire. May damage the whole
unit.
Before assembly
OPERATING INSTRUCTION
1) Make sure the
Ignition Knob is
set to the "OFF"
position.
2) Push in and turn
the ignition knob
anti-clockwise
until a "click"
sound is heard,
check that the burner is now alight.
3) If burner is not alight, return the Ignition
knob back to the "OFF" position, allow the
excess gas to disperse then repeat step 2.

ADJUSTING THE FLAME

• To adjust the flame to the desired
levels please follow the instructions
as shown below.
After assembly
Burner off

Advertisement

Table of Contents
loading

Related Products for COMPANION DC100-09

This manual is also suitable for:

Dc200-09

Table of Contents