Curtis PCGT3 Troubleshooting Manual

G3 primo cappuccino systems
Hide thumbs Also See for PCGT3:

Advertisement

G3 PRIMO CAPPUCCINO SYSTEMS

TROUBLESHOOTING GUIDE

MODELS: PCGT3, PCGT4, PCGT5, PCGT6
Service & Sales
www.wilburcurtis.com
1-800-421-6150

Advertisement

Table of Contents
loading

Summary of Contents for Curtis PCGT3

  • Page 1: Troubleshooting Guide

    G3 PRIMO CAPPUCCINO SYSTEMS TROUBLESHOOTING GUIDE MODELS: PCGT3, PCGT4, PCGT5, PCGT6 Service & Sales www.wilburcurtis.com 1-800-421-6150...
  • Page 2 CHASSIS VIEW HEATING TANK VIEW PART # DESCRIPTION PART # DESCRIPTION 1. WC-37126 KIT, UCM BOARD & LABEL PCGT3 15. WC-37118 KIT, WHIPPER PLATE (3/PKG) 2. WC-5310 TUBING, 5/16” ID x 1/8” W SILICONE 16. CA-1024-05 PILLAR, LOCATION BLACK 3. WC-37054 SOCKET, GEAR 17.
  • Page 3 PCGT4/5/6 PARTS IDENTIFICATION PART # DESCRIPTION PART # DESCRIPTION 1. WC-37126 KIT, UCM BOARD & LABEL PCGT3 18. WC-37008 KIT, TANK LID ROUND 2. WC-5310 TUBING, 5/16” ID x 1/8” W SILICONE 19. WC-5502-01 KIT, PROBE, ASSY WATER LEVEL W/HEX 3.
  • Page 4: Parts Images

    PARTS IMAGES WC-37126 WC-3734 WC-37054 KIT, UCM BOARD & LABEL PCGT3 TUBING, SILICONE SOCKET, GEAR WC-37174 WC-780 WC-6193-0 KIT, GEAR MOTOR & GEAR CONTROL, POWER MODULE HEAT SINK ASSEMBLY WC-3739 CA-1095 CA-1011-05 WHIPPING MOTOR CONNECTOR, ORIFICE WATER BULKHEAD, WATER FITTING...
  • Page 5 PARTS IMAGES CA-1024-05 CA-1008-07K WC-37008 PILLAR, LOCATION BLACK KIT, PROPELLER WHIPPER OFFSET KIT, TANK LID ROUND WC-5502-01 WC-2627 WC-2630 WC-3734 KIT, PROBE ASSY BUSHING, CONICAL BUSHING, CONICAL BLIND KIT, DUMP VALVE WC-904-04 WC-1438-101 WC-523 HEATING ELEMENT SENSOR, TEMPERATURE TANK THERMOSTAT, MNL RESET WC-102 WC-826L WC-37127 / WC-37128...
  • Page 6: Troubleshooting Instructions

    TROUBLESHOOTING INSTRUCTIONS POWER ISSUES The LED light on the front door are not lit: No: Replace Reset Thermostat Verify that the panel breaker is turned on. If Yes: Proceed to #5 okay, proceed STEP 2. Verify that there is 12 vac between pins 1 & Verify that the voltage at the receptacle is 2 on the 14 pin connector at the UPM and correct: L1-N = 120 vac, N-G = 0 vac.
  • Page 7: Dispensing Issues

    TROUBLESHOOTING INSTRUCTIONS - continued TANK FILLING ISSUES Not filling: Overfilling: Is the water turned on? Does the tank continue to fill after the toggle switch has been turned off ? Yes: Verify 120 volts at inlet valve coil Yes: Replace Water Inlet Valve. Yes: Replace Inlet Valve Remove the Orange wire from the Wa-...
  • Page 8 Wilbur Curtis Co., Inc. 6913 Acco Street, Montebello CA 90640 Customer Service: 800.421.6150 | 323.837.2300 csrassistance@wilburcurtis.com Tech Support: 800.995.0417 www.wilburcurtis.com APR/2014 M47_TS_WC_PCGT_revNC...