6.9.3
D+ connection and Solar Control connection
(only for RM 7XX5L appliances)
D+ connection
The D+ control connection must be connected to the respective vehicle
terminal (alternator signal while motor is running).
Solar control input (S+):
CAUTION
The respective solar charging controllers are available from a specialized dealer.
The "Solar" (S+) control connection must be connected to the respective
terminal of the solar charging controller (AES output).
Cable cross-sections
There are no particularly high current flows via the D+ and S+ connection;
therefore no particularly large cross-section is required for these connections
(approx. 1mm²).
6.9.4
Terminal strip
Connections:
A = Ground heating element DC
B = Plus heating element DC
C = Ground electronics
D = Plus electronics
D+ = alternator signal
S+ = AES-input-control signal
(solar charge regulator)
6.9.5
Retrofitting
Retrofitting from the manual energy mode to the automatic energy
mode
For all RM 7XX1 appliances (MES) there is an additional possibility for retrofitting to an
RM 7XX5 device with AES functions.
Please consult your nearest Dometic Customer Service or your specialist dealer.
Connection only when using a solar system with a solar
charging controller with AES output.
(
RM 7xx1 L and RM 7xx5 L models
28
)
on the appliance
D+ S+
-
-
+
+
C D
A B
on the vehicle