Floor standing room sealed gas fired central heating boilers
Hide thumbs Also See for Boston 2 80 RS:

Advertisement

Page 3
TO SHUT DOWN THE BOILER
1. Turn off the electricity supply to
the appliance at the mains.
2. To turn off the pilot: Turn gas control
knob to off position marked 0.
NOTE: The gas control knob cannot
be depressed until ignition restart
interlock device in gas valve has
disengaged. This takes 60 seconds
approximately.
3. Turn off the gas supply at either the
appliance gas cock or the meter.
If your home is to be left unoccupied for
long periods during cold weather, the
whole system should be drained,
unless a frost-stat is fitted. Your
installer will advise you about draining
the system.
IN CASE OF GAS LEAKS
If a gas leak is found or suspected, turn off the gas supply
at the meter immediately and contact your Installer or
Transco (under 'Gas' in the phone directory).
NEVER HANG CLOTHES OR OTHER ITEMS OVER THE
APPLIANCE.
SERVICING YOUR BOILER
We strongly recommend that your Boiler is serviced annually
for economic and safety reasons. Your Installer or British
Gas Service will be able to advise you.
CLEARANCES AROUND THE BOILER
The minimum clear spaces needed
around the boiler are:
Top:
(Free Standing)
13mm ( ½ in)
(Under Work
Top Panel Fitted)
25mm (1 in)
Sides:
(Only when under
Work Top Panel)
10mm (
Front:
3
(In Use)
5mm (
(For Servicing)
400mm (15 ¾ in)
These clearances must not be
obstructed in any way. Blocking the
clearance spaces will result in the
appliance overheating and damage
may possibly occur.
Warnings
THIS APPLIANCE MUST BE EARTHED
Electricity supply:
A standard 230 volt ~ 50Hz supply is required. The
appliance must be protected by a 3 amp fuse.
SAFE INSTALLATION
Installation of this appliance must be carried out by a CORGI
Registered Installer or other competent person and be in
accordance with the relevant requirements of the GAS
SAFETY (Installation and Use) REGULATIONS and any
other regulations applying in your area.
The gas burning compartment of
your boiler Is completely sealed
from the room In which it is fitted.
Products from the combustion of
gas are vented to the outside
through the flue terminal which must
be kept free from obstruction as this
would interfere with the correct
operation of the boiler.
3
/
in)
If the boiler is fitted in a
8
compartment, this should be fitted
with ventilation openings at high and
/
in)
low level which must not be blocked.
16
Occasional checks should be made
to ensure they are clear. The
compartment should be large
enough to house the boiler and
ancillary equipment only.
IT SHOULD NOT BE USED AS A
STORAGE CUPBOARD.