Commissioning, inspection, maintenance
Further details regarding the individual steps
r
r
28
(cont.)
1. Turn on the ON/OFF switch.
Note
The heating output can only be
changed with the burner in opera-
tion.
2. Turn rotary selector "tr" fully clock-
wise, until the display shows
"SERV".
Within 2 s return the rotary selector to
the r.h. control range. The display
shows "A".
3. Select the required max. heating out-
put with rotary selector "tr".
Bars for the selected heating output
flash on the display.
A
■ Position 1 (1 bar) = lower heating
output.
■ Position 6 (5 bars) = upper heating
output.
4. Test selected heating output by
measuring the gas throughput.