Download Print this page

Whirlpool Thin Twin Installation Instructions Manual page 3

240 volt
Hide thumbs Also See for Thin Twin:

Advertisement

For use where
local codes
permit use of
flexible
power
supply
cord.
four-wire
three-wire
receptacle
receptacle
(14-30R)
(lo-30R)
Figure
3
Figure
4
Four-wire
installation
is recommended
(required
for mobile
homes):
The power
supply cord must have four, No.-1 0
copper
wires and match
a four-wire
receptacle
of NEMA Type 14-30R (see
Figure 3). The fourth wire (ground
conductor)
must be identified
with a
green cover and the neutral
conductor
by a white cover.
Three-wire
installation
(if a four-wire
system is not available):
The power
supply cord must have three, No.-10
copper
wires to match
a three-wire
receptacle
of NEMA Type 1 O-30R (see
Figure 4).
Fire Hazard
Use a new UL approved
30 ampere
power supply
cord.
Use a UL approved
strain relief.
Disconnect
power before making
electrical
connections.
Connect
neutral wire (white or center
wire) to center terminal
(silver).
Ground wire (green or bare wire) must
be connected
to green ground
connector.
Connect
remaining
2 supply wires to
remaining
2 terminals
(gold).
Securely
tighten
all electrical
connections.
Failure to do so can result in death,
fire, or electrical
shock.
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL approved
strain relief.
Disconnect
power before making
electrical
connections.
Connect
neutral wire (white or center
wire) to center terminal
(silver).
Ground wire (green or bare wire) must
be connected
to green ground
connector.
Connect
remaining
2 supply
wires to
remaining
2 terminals
(gold).
Securely
tighten
all electrical
connections.
Failure to do so can result in death,
fire, or electrical
shock.
Direct wire
The washer/dryer
can be connected
directly
to fused disconnect
or circuit
breaker
box with four-wire
or three-wire
flexible
armored
or non-metallic
sheathed
copper
cable
(with ground
wire). Do Not use two-wire
with bare
ground
wire. All current-carrying
wires
must be insulated.
A conduit
connector
must be installed
at junction
box. USE ONLY 1 O-GAUGE
SOLID COPPER WIRE. DO NOT USE
ALUMINUM
WIRE. Allow four feet of slack
in the line so dryer can be moved
if
servicing
is ever necessary
.~...$:: neutral
(white or
center
sihrer-colored
j$z center)
terminal
block
screw
,.:.y :.>
::: :::.
..;$:;,:p:
>:.:.:.:.: :
.:::::::::
. . . ..A
,.:.+:.: :
::.+:.:.:
I
.:.: :i.
..:. . . . . .
appliance
harness grounc
1. Disconnect
the power supply.
2. Remove
terminal
block cover (see
Figure 5).
3. Strip 5 inches of outer covering
from
end of cable.
Leave bare ground
wire at 5 inches. Cut l-l /2 inches
from 3 remaining
insulated
wires.
Strip insulation
back
1 inch (see
I
Figure 7).
8
internal
cabinet-
ground.
=a
c-----'-'
1-m
Figure 6
I
Z-external
!i -cabinet-
ground
connect0
:.. :.:.. :.j
314" U.L.-listed
strain relief
\
Electrical connec lion
r
i
1. Disconnect
the power supply.
2. Remove terminal
block cover (see
Figure 5).
3. Install copper,
four-wire
power
supply cord through
strain relief.
4. Remove
the appliance
harness
ground
wire (green with yellow
stripes) from the internal
ground
connector
and fasten under
center,
silver-colored
terminal
block screw.
5. Connect
the ground
wire (green)
of the copper,
four-wire
power
supply cord to the internal
ground
connector.
6. Connect
the neutral wire (white)
of
the power supply cord to the
center,
silver-colored
terminal
screw of the terminal
block.
Connect
the other wires to the
outer terminals.
Tighten screws
firmly.
7. Tighten strain relief screws.
8. Replace
the terminal
block cover.
;$isconnect
b
1 w{
Insulation
1 O-gauge,
J-wire
with ground
wire
(Romex)
Direct
wire preparation
Figure 7
terminal
block
cover
Figure
5
Ws;;ped
Shape the end of
each wire into a 'U"
shaped
hook (see
Figure 8). The bare
ground
wire must be
4-l /2 inches long after
Figure 8
forming
the hook.
4. Install copper,
four-wire
power
supply cable
through
strain relief.
5. Remove
the appliance
harness
ground
wire (green
with yellow
stripes) from the internal
ground
connector
and fasten under
center,
silver-colored
terminal
block
screw.
6. Slide the hook end of the ground
wire (bare) of the four-wire
power
supply cable
under the internal
ground
connector
screw. Squeeze
hook end of wire together.
Tighten
screw.
7. Connect
the neutral
wire (white)
of
the power
supply cable
to the
center,
silver-colored
terminal
screw of the terminal
block using
the same method.
Connect
the
other wires to the outer terminals.
Tighten screws firmly.
8. Tighten strain relief screws.
9. Replace
the terminal
block cover.
This dryer is manufactured
with the
cabinet-ground
conductor
connected
to the NEUTRAL (center)
of of the wiring
harness at the terminal
block. If local
codes do NOT permit this type of
connection,
use "Four-wire
connection"
instructions.
GROUND INSTRUCTIONS: This appliance
must be grounded.
In the event of
malfunction
or breakdown,
grounding
will reduce
the risk of electric
shock by
providing
a path of least resistance
for
electric
current.
If using power
supply cord, the plug
must be plugged
into an appropriate
outlet that is properly
installed
and
grounded
in accordance
with all local
codes and ordinances.
If using a direct wire connection,
this
appliance
must be connected
to a
grounded
metal, permanent
wiring
system; or an equipment-ground
conductor
must be run with the circuit
conductors
and connected
to the
equipment-ground
terminal
or lead on
the appliance.
WARNING - Improper
connection
of the
equipment-ground
conductor
can
result in a risk of electric
shock. Check
with a qualified
electrician
or
serviceman
if you are in doubt
as to
whether
the appliance
is properly
grounded.
Do not modify
the power
supply cord plug. If it will not fit the
outlet,
have a proper
outlet installed
by
a qualified
electrician.
Panel B

Advertisement

loading