Daikin FVQ71BV1B Operation Manual
Daikin FVQ71BV1B Operation Manual

Daikin FVQ71BV1B Operation Manual

Split system
Hide thumbs Also See for FVQ71BV1B:

Advertisement

SPLIT SYSTEM

MODELS
(Floor standing type)
FVQ71BV1B
FVQ100BV1B
FVQ125BV1B

OPERATION MANUAL

Air Conditioner

English
Deutsch
Français
Español
Italiano
ëëçíéêÜ
Nederlands
Portugues
óññêèé

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FVQ71BV1B

  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Deutsch MODELS Français (Floor standing type) FVQ71BV1B Español FVQ100BV1B FVQ125BV1B Italiano ëëçíéêÜ Nederlands Portugues óññêèé...
  • Page 2 Thank you for purchasing this Daikin air condi- Wij danken u voor de a ankoop van deze Daikin- tioner. airconditioner. Carefully read this operation manual before Lees deze bedrijtshandleiding aandachtig door using the air conditioner. It will tell you how to voordat u de airconditioner gebruikt.
  • Page 3 TEST AVAILABLE TEST NOTE Never operate remote controller buttons with hard, pointed objects. This may result in remote controller damage. RZQS125 RZQS71 · 100...
  • Page 4 DISPOSAL REQUIREMENTS VORSCHRIFTEN ZUR ENTSORGUNG INSTRUCTIONS D’ÉLIMINATION ΠΡΟ Ÿ ΠΟΘΕΣΕΙΣ ΑΠΟΡΡΙΨΗΣ REQUISITOS PARA LA ELIMINACIÓN SPECIFICHE DI SMALTIMENTO VEREISTEN VOOR HET OPRUIMEN REQUISITOS PARA A ELIMINAÇÃO Disposal requirements Specifiche di smaltimento Your air conditioning product is marked with this symbol. This means that Il climatizzatore è...
  • Page 5: Table Of Contents

    CONDITIONER ..........9 The unit is individually operated. 10. TROUBLE SHOOTING ........ 10 NOTE • Contact your Daikin dealer in case of changing Important information regarding the refrig- the combination or setting of group control and erant used two remote controller control systems.
  • Page 6 • The precautions described herein are classified Contact professional personnel about attach- ment of accessories and be sure to use only as WARNING and CAUTION. They both contain accessories specified by the manufacturer. important information regarding safety. Be sure If a defect results from your own workmanship, it to observe all precautions without fail.
  • Page 7 Be sure to use a dedicated power supply for Do not place water containers (flower vases, the air conditioner. etc.) on the unit, as this may result in electric The use of any other power supply may cause shocks or fire. heat generation, fire, or product failures.
  • Page 8: Operation Range

    Regarding wiring 3. OPERATION RANGE • All wiring must be performed by an authorized If the temperature or the humidity is beyond the fol- electrician. lowing conditions, safety devices may work and the To do wiring, ask your dealer. Never do it by yourself. air conditioner may not operate, or sometimes, •...
  • Page 9: Operation Procedure

    DISPLAY “ ” (FAN SPEED) • Operating procedure varies with heat pump type This display shows the set fan speed. and cooling only type. Contact your Daikin dealer to confirm your system type. DISPLAY “ ” (AIR FLOW FLAP) • To protect the unit, turn on the main power switch Refer to “ADJUSTING THE AIR FLOW...
  • Page 10 • Micro computer automatically determines Press TEMPERATURE SETTING button and TEMPERATURE and FAN SPEED. program the setting temperature. • This system does not go into operation if the Each time this button is pressed, setting room temperature is below 16°C. temperature rises 1°C.
  • Page 11: Optimum Operation

    B. Adjusting up and down air flow TIMER ON/OFF Horizontal blade Top blade Press the TIMER ON/OFF button. Interlocked The timer setting procedure ends. blades (×6) The display “ ” changes from flash- ing light to a constant light. Bottom blade Refer to figure 4 on page [1] NOTE •...
  • Page 12: Maintenance (For Service Personnel)

    3. Clean the air filter. 8. MAINTENANCE Use vacuum cleaner A) or wash the air filter with (FOR SERVICE PERSONNEL) water B). A)Using a vacuum cleaner ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE IMPORTANT! B)Washing with water •...
  • Page 13: Not Malfunction Of The Air Conditioner

    It is necessary to clean the It does not restart immediately because a safety inside of the indoor unit. Ask your Daikin dealer for device operates to prevent overload of the sys- details on cleaning the unit. This operation tem.
  • Page 14: Trouble Shooting

    While in heating operation: The air conditioner will CODE be in wind direction control immediately after the Measure: Notify your Daikin dealer and inform air conditioner starts operating or when the room him/her of the display. temperature is higher than the set temperature so that the people in the room will not be exposed to an unpleasant wind.
  • Page 15: Indoor Unit

    II. If the system does not properly operate except • If the heat source of the room is excessive for the above mentioned case, and none of the (when cooling). above mentioned malfunctions is evident, Cooling effect decreases if heat gain of the investigate the system according to the fol- room is too large.