Data Initialization; Calibration Inspection; User Calibration Inspection - Pioneer AVH-P2300DVD Service Manual

Dvd rds av receiver
Hide thumbs Also See for AVH-P2300DVD:
Table of Contents

Advertisement

1

[Data initialization]

A
[Outline]
Result of outermost circumference inspection and of calibration inspection (corrected value) are returned to
their initial values.
As for the initialized items, the initial values are written into the EEPROM and the adjustment information
is cleared.
[Display specifications]
B
Conditions for the adjustment completion mark (*) to be lighted up.
Outermost circumference inspection
When the outermost circumference inspection of the calibration for line has been completed normally.
C

Calibration inspection

When the calibration inspection of the calibration for line has been completed normally.
User outermost circumference inspection
When the user outermost circumference inspection of the calibration for line has been completed normally.

User calibration inspection

When the user calibration inspection of the calibration for line has been completed normally.
Conditions for the adjustment completion mark (*) to go out.
Outermost circumference inspection
When the above mentioned lighting conditions are not applicable.
D
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
Calibration inspection
When the above mentioned lighting conditions are not applicable.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
User outermost circumference inspection
When the above mentioned lighting conditions are not applicable.
In case the outermost circumference inspection of the calibration for line or the 16-point adjustment is normally
terminated after normal termination of the outermost circumference inspection for user calibration.
When the adjusted value has been initialized (Data initialize).
E
When the EEPROM has been initialized.
User calibration inspection
When the above mentioned lighting conditions are not applicable.
In case the outermost circumference inspection of the calibration for line or the 16-point adjustment is normally
terminated after normal termination of the outermost circumference inspection for user calibration.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
[Operation specification]
Operational description
F
Selection cursor up movement
Selection cursor down movement
Return to test mode mene
Menu enter
72