KX-TG7841/KX-TG7842/KX-TG7843/KX-TG7844/KX-TG7845/KX-TG365SK/KX-TG7871/KX-TG7872/KX-TG7873/KX-TG7874/KX-TG7875/KX-TG385SK/KX-TGA680
8 Test Mode
8.1.
Engineering Mode
8.1.1.
Base Unit
Important:
Make sure the address on LCD is correct when entering new data. Otherwise, you may ruin the unit.
Soft keys
Navigator key/
?
(Volume) key
1). Press
2). Select "Initial setting" using
3). Enter "7", "2", "6", "2", "7", "6", "6", "4".
4). Select "Write EEP" using
5). Enter " ", " ", " ", " " (Address). (*1)
6). Enter " ", " " (New Data). (*1)
Dial keypad
H/S key operation
{
}
MENU
.
{
}
{>}
then press
SELECT
or
{^} {V}
Select "Set tel line" using
{
}
{>}
then press
SELECT
or
Note: 7262 7664 = PANA SONI
(see letters printed on dial keys)
{^} {V}
{
}
{>}
then press
SELECT
or
{OFF}
{FLASH}
{CALL WAIT}
{^} {V}
or
.
or
.
or
.
29
H/S LCD
C
^
V
Phonebook
INT
SELECT
z
^
V
Initial setting
INT
SELECT
z
^
V
Set tel line
BACK
SELECT
See next page
z
^
V
Set dial mode
BACK
SELECT
Service Mode
Read EEP
Write EEP
BACK
SELECT
Set Addr.:
Default Data
CLEAR
OK