Panasonic CS-E9BKP Service Manual page 38

Room air conditioner
Table of Contents

Advertisement

CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5
Setting the Fan Speed
• Press 4 to select:-
There are five stages of fan speed in addition to
Auto Fan speed.
AUTO
FAN
Heating
When the temperature of the discharge
air increases, the fan speed increases.
Cooling
Changes the fan speed to generate a
cool breeze. The air starts to blow out
approximately 40 seconds after the start
of Cooling or Soft Dry.
Setting the Vertical Airflow Direction.
• Press 5 to select:-
AUTO
AUTO
For COOL/DRY operation.
Swing up/down automatically.
For HEAT operation
AUTO
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.
Louver adjustment range
About 30°
About 30°
About 60°
* Five stages of adjustments can be made in this range.
AUTO HEAT
7
POWERFUL
MODE
1
ON
5
OFF
CHECK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to allow the room
temperature to reach the setting temperature by the
setting time. (Maximum of 35 minutes in advance).
• Once the timer is set, operation will start and stop
at the same time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
Notes
Do not adjust the vertical airflow direction louver downward
during Cooling and Soft Dry. Drops of water may condense
on the air outlet vent and drip down.
Use the remote control to change the vertical airflow
direction louver. Using your hands to adjust the direction
may cause the louver to malfunction. If this happens, stop
operation immediately and restart.
Dry
Setting the Horizontal Airflow Direction.
• Press 6 to select:-
Horizontal
Airflow
Direction
Use this air conditioner under the following
conditions:
The adjustment range is different
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
for each operation i.e. Heating,
Cooling and Soft Dry. (Fig.at left)
Maximum Temperature-Cooling
The angle indicated on the remote
(Maximum Temperature-Heating)
control is different from that on the
Minimum Temperature-Cooling
indoor unit.
(Minimum Temperature-Heating)
The louver angle automatically
changes to prevent condensation
during Cooling and Soft Dry.
When operation stops, the louver
automatically closes.
COOL
DRY FAN
AUTO
AUTO
FAN
CONVENIENCE OPERATION
OFF/ON
Powerful and Sleep modes are available for Automatic
Operation, Heating, Cooling and Soft Dry.
ECONOMY
SLEEP
6
Sleep Mode Operation
AIR SWING
To obtain a comfortable room temperature while sleeping:-
FAN SPEED
• Press 6.
1
2
3
3
• Sleep mode indicator on the indoor unit will light up.
SET
• To cancel this operation, press once more.
4
CANCEL
Sleep Mode Operation Details
2
TIMER
• When the room temperature reaches the set
temperature, the airflow volume will change to low,
RESET CLOCK
automatically
• When used together with the timer, the timer has a
priority.
• Air blows out gently during sleep.
For COOL/DRY operation.
Temperature
S
T
e
e
m
t
p
t
e
i
r
n
a
g
t
u
r
e
For HEAT operation
Temperature
S
T
e
e
m
t
p
t
e
i
r
n
a
g
t
u
r
e
Indoor
Unit
Remote
AUTO
Control
For COOL/DRY operation.
AUTO
Louvers swing horizontally at a fixed
speed.
For HEAT operation
AUTO
When air temperature is low, air is sent
in
. When temperature goes up,
louver swing horizontally at a fixed
speed.
Unit in °C
Outdoor
Indoor
DBT
WBT
DBT
WBT
32
23
43
26
(30)
(-)
(24)
(18)
16
11
16
11
(2)
(-)
(-5)
(-6)
Maximum 1.0°C increase
Maximum 1.0°C increase
3.0°C increase
Sleep Shift
operation starts
Sleep Operation
button is pressed.
0~1 hour
2 hours
4 hours
3 hours
Approximately 10 hours operation
Sleep Operation
Maximum 1.0°C
button is
decrease
pressed.
1.0°C
increase
4.0°C decrease
Sleep Shift
operation starts
0~1
hour
1 hour
5 hours
3 hours
Approximately 10 hours operation
38
Notes
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.8 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
When standby mode is activated, approximately 35 W
of electric power will be consumed on the heat of
compressor to warm up the room quickly. This mode
can be switched off if you do not require it.
Please consult your dealer.
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
Dehumidifies while maintaining the setting
temperature. The Soft Dry Operation is recommended
during the rainy season.
If the room temperature exceeds the setting
temperature, operation switches to Cooling.
The fan speed is rather slow during Soft Dry Operation.
The humidity may not decrease when the indoor
temperature is lower than the setting temperature on
the remote control.
HEAT – Heating Operation
To warm up the room temperature upon your
preference setting temperature.
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced. We recommend that you use an additional
heating device when the outdoor ambient air
temperature is low.
FAN – FAN Operation
Circulates air throughout the room.
Purifies and deodorizes the air if the air purifying filter
is used. Fan Operation is recommended during
seasons in which neither Heating nor Cooling is used.
Powerful Mode Operation
To obtain the set temperature quickly.
• Used in winter to warm yourself quickly upon
returning home (Heating + Powerful).
• Used in summer to cool yourself after a hot bath
(Cooling + Powerful).
• Press 7.
* Powerful mode indicator (orange) on the indoor
unit will light up.
• To cancel this operation, press once more.
Note
• The setting temperature and the fan speed changes
automatically in order to heat, cool or dehumidify the
room quickly.
• The Powerful and Sleep modes can be set during
Automatic Operation.
Operation
Temperature
Fan Speed
HEAT
3.5°C higher
Slightly
2°C lower (For
Automatic
COOL
Stronger
first 20 minutes)
1°C lower (For
DRY
first 20 minutes)