HEATING SEQUENCE
OF OPERATION
NORMAL
HEATING
MODE
ABNORMAL
HEATING MODE
POWER ON
]
No
I
CONTROL SELF-CHECK OKAY?
I
COMBUSTION AIR SLOWER ON FOR I SECOND.
I
TURN INDUCER ON FOR 1 SECOND.
I_
I
IS POLARITY REVERSED?
GAS VALVE OFF. COMBUSTION AIR BLOWER OFF.
INDOOR BLOWER DELAY OFF.
LED#1 ON
LED #2 ON
(RESET CONTROL BY TURNING MAIN POWER OFF,)
POLARITY REVERSED.
LED #1 - FAST FLASH
LED #2 - SLOW FLASH
I SIGNAL IMPROPERI
/
NO
GROUND AT LED
NO
NO
SIGNAL HOLDS
_1
IS THERE
I YES I
S VOLTAGE
_
LOW VOLTAGE SIGNAL AT LED HOLDS
UNTIL UNIT IS
"_1
PROPER GROUND?r_I
ABOVE 75vOLTS?
_
UNTIL VOLTAGE RISES ABOVE75 VOLTS'I
PROPERLY
GROUNDED.
NO
I
GAS VALVE OFF. COMBUSTION AIR BLOWER OFF, I
ROLLOUT SWITCH CLOSED_
i l
INDOOR BLOWER OFF WITH DELAY.
I
"_ll"
I
t'il'_
I
LED #1 - ON. LED #2 - SLOW FLASH.
I
YES I
|
SEQUENCE HOLDS UNTIL ROLLOUT SWITCH CLOSESt
GAS VALVE OFF. COMBUSTION AIR BLOWER ON,
NO
I
INDOOR BLOWER ON HEATING SPEED.
I
LED #1 - SLOW FLASH
I
LED #2 - OFF
GAS VALVE OFF.
COMBUSTION AIR BLOWER OFF.
INDOOR BLOWER OFF WITH DELAY
LED #1 OFF
I
LED #2 SLOW FLASH
(Sequence ho_dsuntil pressure switch
closes or thermostat resets contmt.)
PRESSURE SWITCH WATCHGUARD MODE.
IT
GAS VALVE OFF. COMBUSTION AIR BLOWER OFF.I I
INDOOR BLOWER OFF WITH DELAY.
r-
LED #1 -- OFF. LED #2 - SLOW FLASH.
|
IS S-MINUTE RESET PERIOD COMPLETE?
l
[
BURNER OFF?
(CONTINUOUS FLAME CHECK)
YES
NORMAL OPERATION:
I
LED #1 - SLOW FLASH
LED #2 - SLOW FLASH
+
THERMOSTAT CALLS FOR HEAT:
LED #1 - FAST FLASH
LED #2 - FAST FLASH
YES
i
I
IS COMBUSTION AIR
I
PRESSURE SWITCH OPEN?
I-
YES
I
IS COMBUSTION AIR BLOWER ENERGIZED?
I
(HTG. ACC. ENERGIZED WITH CAB.)
=,I
YES _
I
HAS COMBUSTION AIR PRESSURE
SWITCH CLOSED IN 2.5 MINUTES?
YES
15-SECOND COMBUSTION AIR BLOWER PREPURGEI
INITIATED BY CLOSED PRESSURE SW TCH.
/
YES _
CONTINUED NEXT PAGE
Page 29