Sony hcd-dz230 Service Manual page 2

Hide thumbs Also See for hcd-dz230:
Table of Contents

Advertisement

HCD-DZ230/DZ231/HDZ235
QQ
3 7 63 1515 0
General
DZ230/DZ231:
Power requirements
220 – 240 V AC, 50/60 Hz
Power outputs (DIGITAL MEDIA PORT)
DC OUT: 5 V, 700 mA
HDZ235:
Power requirements
120 V AC, 60 Hz
Power consumption
On: 150 W
Standby: 0.3 W (at the
Power Saving mode)
430 × 63 × 380 mm (17 ×
Dimensions (approx.)
× 15 inches) (w/h/d)
2
1
/
2
incl. projecting parts
Mass (approx.)
4.1 kg (9 lb 1 oz)
Design and specifications are subject to change
without notice.
MODEL IDENTIFICATION
TE
– Rear Panel –
L 13942296513
SPEAKER
FRONT R
FRONT L
SUR R
SUR L
SPEAKER
CENTER
WOOFER
OUT
(DVD ONLY)
Model
DZ230 : AEP, UK models
DZ231 : AEP, UK models
HDZ235 : US, CND models
Abbreviation
CND : Canadian model
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE
WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
www
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
.
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
PUBLIÉS PAR SONY.
2
http://www.xiaoyu163.com
COAXIAL
AM
FM75
DMPORT
EURO AV
OUTPUT(TO TV)
Parts No.
Part No.
2-889-997-0[]
2-889-997-1[]
2-889-997-2[]
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples
of a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2 V AC range are suitable. (See
Fig. A)
To Exposed Metal
Parts on Set
Q Q
3
6 7
1 3
1 5
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
Special Component Notice
The components identified by mark 9 contain confidential
information.
Strictly follow the instructions whenever the components are repaired
and/or replaced.
Notice pour composants spéciaux
Les composants identifiés par la marque 9 contiennent des
informations confidentielles.
Suivre scrupuleusement les instructions chaque fois qu'un
composant est remplacé et / ou réparé.
co
.
9 4
2 8
0 5
8
2 9
9 4
2 8
AC
1.5 k Ω
voltmeter
(0.75 V)
Earth Ground
m
9 9
9 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcd-dz231Hcd-hdz235

Table of Contents