2 Before Repair and Adjustment

TOP PREVIOUS NEXT
Disconnect AC power, discharge Power Supply Capacitors C12 through a 10 O, 5 W resistor to ground. DO NOT
SHORT-CIRCUIT DIRECTLY (with a screw driver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid over current.
Current consumption at AC 120 V, 50 Hz and 60 Hz in NO SIGNAL mode should be 50~130 mA and 40~80 mA
respectively.