Technical Data - Potterton Performa 30 HE Installation & Service Instructions Manual

Hide thumbs Also See for Performa 30 HE:
Table of Contents

Advertisement

Appliance Type
Appliance Category
CAT II
Heat Input CH
Max
Min
kW
30.5
11.9
Heat Output CH (Non-Condensing)
Max
Min
kW
29.6
11
Heat Output CH (Condensing)
Max
Min
kW
31
11.3
Heat Input DHW
Max
kW
30.5
Heat Output DHW
Max
kW
29.6
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
m
3
/h
3.22
Burner Pressure (Natural Gas - G20)
Max Rate
mbar
12.1 ± 0.5
Inlet Pressure (Natural Gas - G20)
mbar
20
Burner Injector (Natural Gas - G20)
15 x 1.25mm Diameter
Electrical Supply
(Appliance must be connected to an
earthed supply)
Power Consumption
External Fuse Rating
Internal Fuse Rating
Fuse 2A Fast Blow to BS 4265
SEDBUK Declaration For Performa 30 HE
The seasonal efficiency (SEDBUK) is 87.3% (89.4% LPG)
Band B
This value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by 0051.
LPG Propane - G31
Burner Injector 15 x 0.77mm diameter
Burner Pressure
Max Rate
Propane
mbar
32.3 ± 0.5
Inlet Pressures
mbar
8
C
C
Electrical Protection
12
32
IPX5D
2H 3P
NO x Class
Condensate Drain
Flue Terminal
Dimensions
Connections
Gas Supply
Central Heating Flow
Central Heating Return
Cold Water Mains Inlet
DHW Flow
Pressure Relief Discharge -
Outercase Dimensions
Casing Height
Overall Height Inc Flue
Elbow
Casing Width
Casing Depth
Clearances
Above Casing
Below Casing
Front
Min Rate
Front
2.1 ± 0.2
L.H. Side
R.H. Side
*NOTE: The boiler can be operated with a
clearance of 5mm at the right. This is also
sufficient for routine maintenance.
However a clearance of 20mm is required
230V~ 50H z
if it is necessary to remove the secondary
heat exchanger. This should be
considered when siting the appliance and
in the event of any subsequent alterations
180W
in the area of installation
3A
Weights
Packaged Boiler Carton
Installation Lift Weight
Min Rate
5.2 ± 0.2
37
4.0

TECHNICAL DATA

4.1
Performa 30 HE
3
1" BSP
Diameter
100mm
Projection
125mm
copper tails
-
22mm
-
22mm
-
22mm
-
15mm
-
15mm
15mm
-
780mm
-
965mm
-
450mm
-
345mm
200 mm Min
200 mm Min
450 mm Min
(For Servicing)
5 mm Min
(In Operation)
5 mm Min
5 mm Min
(In Operation)
20mm Min
(See Note*)
kg
54
44
Pump - Available Head
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
0
200
400
600
Flow Rate (l/h)
Central Heating Primary Circuit
Pressures
Safety Discharge
Max Operating
Min Operating
Recommend Operating
DHW Circuit
bar
Pressures
Max Operating
8
Min Operating
0.2
Min Operating Pressure
at 12.7 l/min
0.96
Flow Rates
l/min
DHW Flow Rate
@ 30
o
C Rise
14.1
DHW Flow Rate
@ 35
o
C Rise
12.1
Min Working
DHW Flow Rate
2.5
Pump
Available Head
See graph below
Expansion Vessel - (For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure
0.5
litre
Max Capacity of
CH System
125
Primary Water Content
1.2
of Boiler (unpressurised)
Temperatures
C.H. Flow Temp
(adjustable)
35°C to 85°C
max
D.H.W. Flow Temp
(adjustable)
35°C to 65°C
max
dependent upon flow rate
800
1000
1200
Publication No. 5111815
bar
3
2.5
0.5
1-2
(± 5°C)
(± 5°C)