Kenmore W10213167A Use & Care Manual page 26

Table of Contents

Advertisement

Available languages

Available languages

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
*
Particulate Class I
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Atrazine
Asbestos
Live Cysts
Turbidity
Alachlor
Endrin
Ethylbenzene
Lindane
Chlorobenzene
Tetrachloroethylene
Styrene
TTHM
MTBE
VOC
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model P1KB1: The filter monitor system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you
replace the filter.
Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Use replacement cartridge P1RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./$71.99 Canada.
Prices are subject to change without notice.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
26
Base Grille Water Filtration System
Model P1KB1/P1RFKB1 Capacity 100 Gallons (379 Liters)
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, O-Dichlorobenzene, Cysts, Turbidity, Asbestos, Lindane,
Tetrachloroethylene, Endrin, Alachlor, Styrene, Chlorobenzene, Ethylbenzene, TTHM, MTBE and VOC.
NSF Reduction
Average
Requirements
Influent
50% reduction
2.10 mg/L
85% reduction
21000000#/mL
NSF Reduction
Average
Requirements
Influent
0.010 mg/L
150 ug/L
0.010 mg/L
160 ug/L
0.002 mg/L
5.8 ug/L
0.002 mg/L
6.1 ug/L
0.005 mg/L
15 ug/L
0.6 mg/L
1900 ug/L
0.003 mg/L
14 ug/L
0.003 mg/L
9.0 ug/L
99%
130 MFL
>99.95%
96,000/L
0.5 NTU
12 NTU
0.002 mg/L
41 ug/L
0.002 mg/L
5.9 ug/L
0.7 mg/L
2100 ug/L
0.0002 mg/L
1.9 ug/L
0.1 mg/L
2100 ug/L
0.005 mg/L
14 ug/L
0.1 mg/L
2200 ug/L
0.080 mg/L
480 ug/L
0.005 mg/L
15 ug/L
0.05 mg/L
300 ug/L
Influent Challenge
Maximum
Concentration
Effluent
2.0 mg/L ± 10%
0.05 mg/L
At least 10,000 particles/mL
140000 #/mL
Influent Challenge
Maximum
Concentration
Effluent
0.15 mg/L ± 10%
1.0 ug/L
0.15 mg/L ± 10%
2.0 ug/L
0.006 mg/L ± 10%
0.2 ug/L
0.006 mg/L ± 10%
0.4 ug/L
0.015 mg/L ± 10%
0.5 ug/L
1.8 mg/L ± 10%
0.7 ug/L
0.015 mg/L ± 10%
1.0 ug/L
0.009 mg/L ± 10%
0.5 ug/L
7
8
††
10
to 10
fibers/L
0.17 MFL
50,000/L min.
1/L
11 ± 1 NTU
0.4 NTU
0.04 mg/L ± 10%
1.0 ug/L
0.006 mg/L ± 10%
0.2 ug/L
2.1 mg/L ± 10%
0.5 ug/L
0.002 mg/L ± 10%
0.02 ug/L
2.0 mg/L ± 10%
1.1 ug/L
0.015 mg/L ± 10%
0.5 ug/L
2.0 mg/L ± 10%
ND (0.5)
0.45 ± 20%
3.9 ug/L
0.015 ± 20%
1.3 ug/L
300 ± 30 ug/L
ND (0.5)
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Reduction
97.6
**
99
Minimum %
Reduction
99.3
99.4
96.6
93.4
96.7
99.9
91.5
94.5
99
99.99
96.7
97.6
96.5
99.9
99
99.9
96
99.9
99.2
91.3
99.8
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 L/min) @ 60 psi
Average %
Reduction
97.6
99.5
Average %
Reduction
99.3
99.3
96.6
95.3
96.7
99.9
92.8
94.5
99
99.99
98.5
97.6
96.6
99.9
99
99.9
96.4
99.9
99.8
96.2
99.8

Advertisement

Table of Contents
loading