Sg2-Fpt Optical Transmitter; Figure 5-17 Sg2-Fpt; Table 5-4 Sg2-Fpt Features - Motorola Starline SG 2000 Installation And Operation Manual

Telecommunications optical node
Table of Contents

Advertisement

Feature
Transmitter enable
Fault indicator
S G 2 - F P T O p t i c a l T r a n s m i t t e r
The SG2-FPT is a non-isolated Fabry-Perot return-path optical transmitter designed for use in the SG
2000 node platform. It has a nominal optical output power of 0.4 mW and can be used in conjunction
with an AM-RPR, AM-OMNI-RPR/2, or other similar return path optical receiver. Figure 5-17
illustrates the SG2-FPT:
F i g u r e 5- 17
SG 2- F PT
Table 5-4 provides information on the user-related features of the SG2-FPT:
T ab le 5- 4
SG 2- F PT f eat ur e s
Feature
Optical power test point
Laser current test point
Description
A green LED that provides visual indication of the transmitter's
enable status.
A single red LED that lights when the hybrid current is outside the
normal operating range, the laser output power is below normal
limits, or the laser current is above normal limits. Because the laser
output requires a short period of time to stabilize, it is acceptable
for the fault indicator to illuminate during the stabilization interval
(approximately 2 seconds). Note that the module must be enabled
for the fault indicator to function.
SG2000
Optical Transmitter
OPTICAL
POWER
CURRENT
(1 V/mW)
Description
This test point enables monitoring of the optical output level of the
module. The nominal scale factor is 1.0 V/mW. The optical power
test point voltage is between 0.375 V and 0.425 V (optical power of
0.375 mW through 0.425 mW) when the module is enabled under
normal operating conditions. Note that the optical power test point
does not track changes in optical power due to the laser tracking
error.
This test point enables monitoring of the current drawn by the laser
diode. The nominal scale factor is 1.0 V/A. The laser current test
point voltage is between 4 mV through 90 mV (laser current of
4 mA through 90 mA) when the module is enabled under normal
operating conditions. The laser current is expected to vary widely
with changes in temperature, but should always remain between
the limits.
S G 2 0 0 0 I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l
O p e r a t i o n
SG2-FPT
O
F
LASER
N
A
U
ASSEM BLED
(1 V/A)
L
IN MEXICO
T
5 - 1 5

Hide quick links: