PROGRAMMING - H3E ELEMENT Continued
1. Press and release the hidden button. The display will show P1. Display will now show
the "SET" temperature. Press the (+) button to increase the temperature set point,
or the (-) button to decrease the set point.
Range: 15°C (60°F) to 96°C (205°F). Default: 93°C.
2. After the Tank Temperature is entered, press and release the hidden button once
more. The display will read P2, then show the ready temperature set point.
Range: 2°C to 10°C below the "SET" temperature. Default: 90°C.
3. Press the (+) button to increase, or the (-) button to decrease the set point.
4. Press and release the hidden button once more. The display will read P3. This
screen will allow you to turn the "Auto" energy save mode ON/OFF. Default: OFF.
NOTE: Turning off this function will disable "P4" and "P5".
5. Press and release the hidden button once more. The display will read P4.
This will toggle the energy save mode from 60°C (140°F) or tank heater "OFF".
6. Press and release the upper hidden button once more. The display will read P5.
This is the time delay from the last refi ll to the activation of energy save mode.
Range: 4 hours to 24 hours.