INSTALLATION
Continued
5. Use the two finger holes in the firebox
bottom to carefully lift up and remove
the firebox bottom.
6. Locate duplex outlet mounted to sup-
port bracket in lower right hand side of
firebox. Remove screw holding duplex
outlet to support bracket in bottom of
firebox. Remove duplex outlet (see Fig-
ure 22).
7. Clamp electrical cable hard-wiring into
firebox through smallest hole using
strain relief fitting provided (see Fig-
ure 23).
8. Connect electrical cable to duplex outlet.
Match wire colors to those on duplex
outlet. Be sure to connect ground wire.
9. Replace duplex outlet with screw.
10. You may now install GA3700 Blower
Accessory if desired, see Installing Op-
tional Blower Accessory, page 11.
11. Replace firebox bottom with four
Phillips screws.
12. If applicable carefully replace firebrick
panels in reverse order (see Figures 18
through 20, page 12).
Screws
Finger
Holes
Firebox
Bottom
Screws
Figure 21 - Removing Firebox Bottom
105605
Screw
Figure 22 - Removing Duplex Outlet
Small Hole
Figure 23 - Installing Strain Relief Fitting
into Electrical Access Hole
13
OWNER'S MANUAL
Electric
Cables
Duplex
Outlet
Support
Bracket