Vanguard FB36NCA Owner's Operation And Installation Manual page 12

Unvented (vent-free) logmate universal firebox
Table of Contents

Advertisement

VANGUARD
UNVENTED (VENT-FREE) LOGMATE
INSTALLATION
Continued
3.
Place the blower against the lower rear
wall of the firebox outer wrapper with
the exhaust port directed upward. Align
the holes in top mounting tabs of blower
with holes in wall of wrapper (see Fig-
ure 16). Using 2 screws provided, mount
blower and tighten screws securely.
4. Be certain that all wire terminals are
securely attached to terminals on
blower motor and that the screw retain-
ing the green ground wire is tight.
5. Locate the plastic hole plug installed
in the 3/8" diameter opening in the
lower right side of the firebox front
panel (see Figure 17). Remove the
plastic plug and discard.
Lower Rear Wall of
Firebox Wrapper
Blower
Screws
Exhaust Port
Figure 16 - Mounting Blower to Firebox
Plastic
1
Hole Plug
Figure 17 - Installing Plastic Bushing for
Power Cord
HARD-WIRING FIREBOX
For Built-in Installation of
Circulating Models Only
Models FB36CB, NLFB36C, and FB42CA
can be hard-wired to the duplex outlet lo-
cated inside the firebox bottom if desired.
This allows the GA3700 Blower Accessory
to be plugged into the duplex outlet.
NOTICE: A qualified electrician
must connect electrical wiring
to duplex outlet for built-in in-
stallation. Follow all local
codes. In absence of local codes
follow The National Electric
Code ANS/NFPA 70.
1.
If your firebox has a brick liner use a
Phillips screwdriver, remove the screw
and retainer bracket at the top of the
firebrick liner panel on the left side.
Carefully remove the left panel from
the firebox. Repeat for firebrick liner
panel on right side.
Left Side Firebrick Liner Panel
Top
Mounting
Product
Tab
Identification
Label
Figure 18 - Removing Side Panel
Plastic
Bushing
1
/
" Hole
2
2.
3.
4.
Retainer
Bracket
Rear Firebrick
Liner Panel
Screw
Figure 19 - Removing Rear Firebrick Liner
Panel
Figure 20 - Removing Bottom Firebrick
Floor
12
®
FIREBOX
Remove the screw and retainer bracket
at the top of the brick liner panel in the
back of the firebox. Do not let the panel
fall after the bracket is removed. Care-
fully remove the rear firebrick liner
panel from the firebox.
CAUTION: Do not let the fire-
brick liner panel fall after the
bracket is removed.
Carefully lift and remove the bottom
firebrick floor from bottom of firebox.
Remove the four Phillips screws in fire-
box bottom.