Conversion To Different Category Adm 40 Through 115 - A.O. Smith ADM - 40 Installation, User And Service Manual

Commercial atmospheric water heater
Table of Contents

Advertisement

4
4.1
Conversion to
different category
ADM 40 through 115
Legend
Only applicable numbers are
mentioned.
1. burner pressure regulator
4. gas control connector
5. blank plate
6. supply pressure test nipple
7. gas control
34
Conversion to a different gas category
1. Isolate the appliance from the power supply (10.3 "Isolating the appliance
from the mains").
2. Shut off the gas supply.
Caution
The burner can be hot.
3. Unscrew the cover plate (1) from the burner support.
4. Use a suitable tool to remove the retaining strips (2). Note that the retaining
strips have very sharp edges. Withdraw the retaining strips straight upwards.
Note
The radiation shield / condensation tray can be temporarily loosened to
simplify disassembly of the burner.
5. Remove the burners one by one from their brackets at the front. To do this,
you first move them away from you and then downwards. The orifices will
now be accessible
6. Remove the orifices.
7. Select and fit the correct orifices from the conversion kit, based on the gas
data table (3.4.3 "Gas data"). The orifice diameter is stamped on the orifice
itself, see (3).
8. Re-fit the burners back in their original position.
9. Re-fit the retaining strips.
10. If the radiation shield / condensation tray was loosened, re-fasten it.
Conversion of gas control
6
7
4
1
Instruction manual ADM
is
5
IMD-0131 R1