Aiphone LEF-3 Installation & Operation Manual page 14

Lef series
Table of Contents

Advertisement

Operation Plate for LEF-3
Sub/door call-in
Fill in
1
directory
Station-
selector (3)
AIPHONE
LEF-3
Voice vol.
BG-10C All Call, Chime, and Music Adaptor:
Music is selectively distributed to all LEF station speakers, controlled by switch settings in BG-10C.
When any station initiates a call, the music mutes automatically.
When door station calls in, chime tone is transmitted to selected inside stations, controlled by switch settings.
Privacy (PRIV) feature:
When PRIV button is depressed, the calling master can call into a station in "privacy" mode, but the "listen" mode is cut off.
To release from PRIV, press TALK momentarily.
LE sub stations:
To call a master station:
1.
Simply press the CALL button, which rings an electronic tone (for as long as button is held). The corresponding LED on
the called master station(s) will be lit for approximately 20 seconds.
2.
When master replies, speak handsfree.
When called by a sub station while talking to another station:
The station's call-in LED will light for approx. 20 sec., but call tone is muted. (NOTE: If A/B switch is set to "B" position, the
call tone will be heard at a muted level, even if the receiving station has another station selected.) Depress OFF button to
disconnect from original call, the depress the selector button with lit call-in LED to answer the next call.
7
7
LEF system Troubleshooting Guide
Problem
1. No call tone or call-in LED when sub
calls master (2-wire connection).
2. Call tone works, but no
communication, or communication
works, but no call tone.
3. Master stations cannot call each
other.
4. Call tone is too loud or too soft.
ON LED
In-use
2
3
CALL
OFF OCCUPIED
PRIV.
TALK
VOICE
VOL.
OFF (standby)
Privacy
Make sure jumper is installed between E & – at the subs and the master
station.
Same as above; E & – jumper must be in place. If 3 wires are used, 1 &
– are for call-in, and 1 & E are for communication. Check continuity and
connection of wires.
The C terminal of the master means "CALL", and allows master-to-master
communication. Make sure the C terminal of each master is connected to
a designated # terminal on all other masters. (example: C at master 1
connects to the 1 terminal of all other masters.)
Adjust call tone volume with slide switch located under operation plate.
(Remove plate and use small screwdriver to adjust.)
Operation Plate for LEF-5, 10, 10S
Sub/door call-in
Fill in
1
2
3
4
directory
Station-
selector
(5 or 10)
AIPHONE
VOICE VOL.
LEF-10S
Voice vol.
In-use
– 14 –
ON LED
5
6
7
8
9
10
OFF
CALL
OCCUPIED
ALL CALL
PRIV.
TALK
All call
Door release
Privacy
LEF-10S only
Solution
OFF
(standby)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lef-5Lef-10sLef-10Lef series

Table of Contents