Panasonic SA-AK250GCP Service Manual page 48

Cd
Table of Contents

Advertisement

SA-AK250GCP
14.1.5. Bias Voltage Check
1. Connect an electrical voltmeter. (Fig 12) ( Fig 9 for location of test points)
2. Set the function to "TAPE" position.
3. Insert a normal blank cassette tape (QZZCRA).
4. While pressing and holding down [REC(
pressing the buttons till the recording pause mode is activated.)
5. Check that the output level is within the standard range.
Standard Range: 16 ± 3mV
14.1.6. Bias Frequency Check
1. Connect a digital frequency counter (Fig 13).
2. Set the function to "TAPE" position.
3. Insert a normal blank cassette tape (QZZCRA) and press "REC" mode on main unit.
4. Check that the output frequency is within the standard range.
Fig. 10
Fig. 11
/
)] button, press [TAPE(
Fig. 12
Standard Value: 98 ±8 kHz
Fig. 13
48
)] button to pause the recording mode. (Repeat

Advertisement

Table of Contents
loading

Table of Contents