Technics SA-EX310 Service Manual page 13

Av control stereo receiver
Table of Contents

Advertisement

NORMAL WAVEFORMS OF AMPLIFIER CIRCUIT AND LIKELY FAULTY BLOCKS
TP
CD player
C4
S4
0.5msec 200mV*
C5
area
S5
0.5msec 5V*
Measurement conditions.
control (VR512) and Bass control (VR511) positions
*Volume control position (VR501) for these test
CIRCUIT BLOCKS
OVERLOAD DETECTION FUNCTION
The HIC protection circuit functions if any cord at a speaker terminal is short-circuited or if the unit overheats because of i m proper
operation. At the same time, OVERLOAD scrolls across the FL display.
In this state, all keys remain in operative; if any key is pressed, SWITCH OFF POWER scrolls across the FL display.
If an overload occurs, immediately power off the unit and check the speaker connection, venting holes and cooling fans. After
fixing any faults, power on the unit again and check for proper operation.
If no defects are found, or if the unit remains overload after it is power on again, check the circuit for faults.
Tape deck
1msec 500mV
1msec 10V
Likely faulty block if the normal
AF oscillator
waveform shown at the left is not
present.
Power limiter block
Q551 to Q552 & area
1msec 1V
Main amplifier block IC601 &
IC602 & area
1msec 1V*
Volume control (VR501), Tremble
:
:
SA-EX310