Samsung SR-L676EV Service Manual page 13

Hide thumbs Also See for SR-L676EV:
Table of Contents

Advertisement

No
Item
1
R1-Sensor
Refrigerator "LOW"
2
R2-Sensor
Refrigerator
"LOW · M
3
RD-Sensor
Refrigerator "M
4
Air-Sensor
Freezer "LOW"
5
F-Sensor
Freezer "L O W" · Med"
6
FD-Sensor
Freezer "M
7
Geared-
Refrigerator "HIGH"
Motor
Samsung Electronics
Display LED
• R-room left sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room left right sensor
e
housing disconnection.
d"
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
e
d"
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Outer sensor housing
disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• F-room sensor housing
disconnection.
• Faulty connection
• Wire open or short.
• Faulty sensor.
• R-room defrost sensor
e
d"
housing disconnection.
• Faulty connection.
• Wire open or short.
• Faulty sensor.
• Faulty geared-motor
• Faulty reed-switch
housing disconnection.
• Faulty connection.
(Self-diagnosis Display Table)
Symptom
Remark
R1-Sensor temperature is
over +50˚C or below –50˚C.
R2-Sensor temperature is
over +50˚C or below –50˚C.
RD-Sensor temperature is
over +50˚C or below –50˚C.
Outer-Sensor temperature
is over +50˚C or below
–50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
F-Sensor temperature is
over +50˚C or below –50˚C.
Square wave not detected
by reed-S/W.
15

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Sr-l678evSr-l626evSr-l628ev