(4)
Defect processing during initialization
Table 4.3 shows each combination of control flag specification values and the contents of
processing executed by the IDD. Furthermore, see Chapter 3 "Data Format" of the "Product
Manual" concerning alternate block allocation processing methods.
Table 4.3
CDB Byte 1
FmtData CmpLst
Defect
List
Format
0
–
– – –
(Note 4)
1
0
d d d
(Note 1,
Note 2,
Note 3)
d d d
1
0
(Note 1,
Note 2,
Note 3)
1
1
d d d
(Note 1,
Note 2)
1
1
d d d
(Note 1,
Note 2)
1
0
1 0 0
1 0 1
(Note 3)
FORMAT UNIT command defect processing (1 of 2)
Header
FOV
DPRY
Defect
List
Length
(Format parameters not
transferred)
0
0
Zero
1
0
1
1
Zero
0
0
Zero
1
0
1
1
Zero
0
0
>0
1
0
C141-E054-02EN
Defect Processing Method
Alternate block allocation is
performed for defects registered in
the P List.
The previously existing G List is
erased.
Alternate block allocation is
performed for defects registered
in the P List and the previously
existing G List.
The previously existing G List is
saved.
Alternate block allocation is
performed for defects registered
in the previously existing G List.
The P List is saved, but it is not
used in defect processing.
The previously existing G List is
saved.
Alternate block allocation is
performed for defects registered
in the P List.
The previously existing G List is
erased and it is not used in defect
processing.
Neither the P List or the G List is
used in defect processing
(alternate block allocation
processing is not performed.)
The P List is saved, but the
previously existing G List is
erased.
Alternate block allocation is
performed for defects registered in
the P List, in the previously
existing G List and the defects
described in the D List transferred
from the INIT.
The D List is added to the
previously existing G List.
4 - 101