VERTICAL FLUE TERMINAL Ø 60/100 MM INSTALLATION OPTIONS
This type of installation can be carried out both on a flat or pitched roof by fitting a terminal, an appropriate weathering
tile and sleeve, (supplementary fittings supplied on demand).
L max = 10 m
L max = 10 m
L max = 8 m
L max = 9 m
... SEPARATED FLUE-AIR DUCTING
This type of ducting allows to disengage exhaust flue gases both outside the building and into single flue ducts.
Comburant air may be drawn in at a different site from where the flue terminal is located.
The splitting kit consists of a flue duct adaptor (100/80) and of an air duct adaptor.
For the air duct adaptor fit the screws and seals previously removed from the cap.
flue duct adaptor
Intake air duct adaptor
Figure 10
The 90° bend allows to connect the boiler to flue-air ducting regardless of direction as it can be rotated by 360°. It can
moreover be used as a supplementary bend to be coupled with the duct or with a 45° bend.
13
INSTRUCTIONS FOR THE INSTALLER