Back flue outlet (Diagram 1-9)
1. Core drill 127mm hole (5").
6. Cut the outer flue 80mm longer
than the inner wall finish.
Fig. 22f
8. Ensure that the inner metal flue is pushed into the
terminal, as shown.
9. Lift boiler onto the wall bracket with flue in place,
and engage the outer flue into the adapter. Secure
the boiler using the nuts & washers supplied.
60mm
Fig. 22h
Supplied By www.heating spares.co Tel. 0161 620 6677
FERROLI F30
2. Push through the outer flue.
Fig. 22a
7. Insert the aluminium flue pipe into
white plastic outer flue, making
sure the aluminium pipe sits fully
and centrally into the flue termi-
nal. Mark the aluminium flue pipe
at the point it is flush with the
plastic outer flue, add 60mm to
this mark and cut the aluminium
inner flue pipe at this point.
NOTE: Ensure the end is cut square
de-burred & lubricated with sili-
cone grease.
3. Gently pull back until wall seal
Fig. 22b
60mm
60mm
9. Make sure the inner flue is fully engaged in the
flue terminal, Re-attach the fan as shown in fig
21h. Secure bottom of boiler using two screws
and washers provided.