[0d Indoor TC sensor error]
Is CN05 (TC sensor connector)
connected properly?
YES
Is TC sensor resistance value
(10 kΩ at 25°C) normal?
YES
NO
NO
Indoor P.C. board is defective.
– 42 –
FILE NO. SVM-06017
Connect CN05 properly.
Replace TC sensor.
Replace P.C. board.