Clearances to Combustibles
m
C
C
inimum
learanCes to
E & J = 32.0" (813mm) from Top Facing or Mantel to Bot-
tom of Insert
F 52.
= 10.5" (267mm) from Edge of Glass to Side Facing
or Side Wall
h
p
earth
roteCtion
G = Minimum Hearth Protection from Front of Insert*
H = Vertical Distance from Insert Bottom to Combustible
Material.
G
13"(330mm)
H
0"(0mm)
Note: Hearth protection to be min. /8" (10mm) thick non-
combustible or equivalent, with a k factor of .84.
i
l
nsert
eveling
At each front and rear corner of the insert is an adjustable leg
provided to level the insert should the hearth of the fireplace
be uneven. To adjust the legs, loosen the two 5/32" allen head
screws, move the leg to the desired height, and then tighten
the screws. Repeat these steps for each adjusting leg.
ombustibles
10"(254mm)
0"(0mm)
2"(21mm)
4"(102mm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
C
MANTEL
Mantel
TRIM
Trim
E
G
Hearth / Floor Protection
Figure 4
learanCes
F
C L
H
J
7