Lighting Instructions; To Turn Off Gas To Appliance - Montigo L42DF ST Installation & Maintenance Manual

L-series indoor residential fireplace
Table of Contents

Advertisement

L42DF-ST* Indoor Gas Fireplace
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn "ON" manual "ON/OFF" switch located below the hori-
zontal access panel (if available).
4. Turn Incoming gas valve to the ON" position.
5. Wait 5 minutes to clear out any gas. If you smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.
Stepper Motor
SW1
LED1
LED2
SW1 = Programing Button
LED1 = Red Diagnostic Light
LED2 = Amber Programing Remote Control Light
Typical Control Module shown
1. Turn off fireplace using wall switch or remote control.
2. Remove the lower Horizontal access panel.
Page 28
Operation
SIT Proflame 2 Electronic Ignition

Lighting Instructions:

Main ON/OFF Switch
Main Harness
Sensor
Igniter
3.15A Fuse
Power

To Turn Off Gas To Appliance:

6. Turn fireplace "ON" using wall switch or remote control.
7. If the Fireplace does not light, the System will cycle through
two trials, (one minute audible clicking, thirty seconds of
silence, and then another one minute of audible clicking).
If the system locks out due to inadequate gas flow, refer to
"Troubleshooting" in instruction guide.
8. After completion of the information in the Troubleshooting
section, Repeat step 5.
9. If the system will not function correctly, follow the instruc-
tions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
Manifold Pressure
Test Connection
Inlet Pressure
Test Connection
Gas Valve
3. Turn the incoming gas control valve to "Off".
4. Replace the lower Horizontal access panel.
Hi Lo Adjustment
Pilot Adjustment Screw
XG0182- 151126

Hide quick links:

Advertisement

Table of Contents
loading