Maintenance; Maintenance Recommendations; Maintenance Schedule; Product Specifications - DeWalt DXGNR 7000 Instruction Manual

Hide thumbs Also See for DXGNR 7000:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance

Maintenance Recommendations

Regular maintenance will improve performance and
extend generator life. See a qualified dealer for service.
Generator warranty does not cover items subjected to
operator abuse or negligence. To receive full warranty
value, operator must maintain generator as instructed in
this manual, including proper storage as detailed in Win-
ter Storage and Long Term Storage.
Call 1-888-431-6871 with questions
NOTICE:
about component replacement.

Maintenance Schedule

Follow maintenance schedule intervals, whichever
occurs first according to use.
Adverse conditions will require more fre-
NOTICE:
quent service.
All required service and adjustments
NOTICE:
should be each season as detailed in the
following chart.
Maintenance
As
Task
Needed
Clean Exte-
X
rior
Sur-
faces
Check
Engine Oil
Level
Change
Engine Oil *
Clean/
Replace Air
Filter **
Replace
Spark Plug
Check/
Adjust
Valve
Clearance
***
* Change engine oil after first 30 hours of operation.
Change every month when operating under heavy
load or in high temperatures.
** Clean air filter more often under dirty or dusty condi-
tions. Replace parts if they cannot be adequately
cleaned.
*** Check valve clearance after first 50 hours of oper-
ation and adjust if necessary.
Owner's Manual for Portable Generator
At
Every
Every
Each
100
Season
Use
Hours
X
X
X
X
X
X
X

Product Specifications

Generator Specifications
Rated Power
Surge Power
Rated AC Voltage
Rated AC Load
Current @ 240V
Current @ 120V
Rated Frequency
Phase
Unit Weight
Unit Dimensions
** Operating Temperature Range: -18 deg. C (0 deg.
F) to 40 Deg. C (104 Deg. F). When operated above
25 deg. C (77 deg. F) there may be a decrease in
power.
Every
** Maximum wattage and current are subject to, and
limited by, such factors as fuel Btu content, ambient
200
Hours
temperature, altitude, engine condition, etc. Maximum
power decreases about 3.5% for each 1,000 feet
or
Yearly
above sea level; and will also decrease about 1% for
each 6° C (10° F) above 16° C (60° F) ambient tem-
perature.
Engine Specifications
Displacement
Spark Plug Part
Number
Spark Plug Type
Spark Plug Gap
Gasoline Capacity
Oil Type
Oil Capacity
Run Time (50% Load)
Battery
Maintenance
7.0 kW**
8.75 kW
120/240
29.2 Amps**
58.3 Amps**
60 Hz @3600 RPM
Single Phase
90.7 kg (200 lb.)
L = 692mm (27.25") x W =
696mm (27.4") x H = 724mm
(28.5")
420cc
0J00620106
NHSP LDF7TC
0.028-0.031 inch or (0.70-0.80
mm)
28.4 L (7.5 U.S. gallons)
Before Starting
See Chart in
Generator
1.0 Liters (1.06 qt.)
10.5 Hours
12 VDC, 10 Amp Hour
13

Hide quick links:

Advertisement

Table of Contents
loading