7. Removing the power/ballast unit
7-1. Remove the fixing screw for the rear-R/C PWB.
7-2. Remove 4 fixing screws, 4 WH bosses and the edge saddle for the ballast unit.
7-3. Remove 11 fixing screws and 5 WH bosses for the power unit.
7-4. Remove 4 fixing screws for the fan.
8. Removing the peripheral units
8-1. Remove 4 fixing screws for the front adjuster foot.
8-2. Remove 8 bracket fixing screws and remove the bracket-A and bracket-B.
Power PWB
Rear-R/C PWB
7-4
Air Flow
Fan
Ballast PWB
7-2
Edge saddle
7-2
Bracket-A
8-1
Front Adjuster Holder
Height Adjust Button
Front Adjuster Foot
7-3
7-3
7-1
7-3
7-2
7-3
7-3
Ballast Unit
8-2
Bracket-B
20
7-3
Power Unit
7-3