Korg Kp3 Test Mode; Functions Of Switches; Error Code; Internal Inspection - Korg KP3 Service Manual

Hide thumbs Also See for KP3:
Table of Contents

Advertisement

KORG KP3 TEST MODE

How to enter the simple TEST MODE
Pushing following switches, and turn the power ON.
CONNECTION[SEND] & [7] + [TAP/RANGE]
CONNECTION[SEND] & [5] + [TAP/RANGE]
Other test modes for repairing
Pushing following switches, and turn the power ON.
CONNECTION[SEND] & [1] + [TAP/RANGE]
CONNECTION[SEND] & [2] + [TAP/RANGE]
CONNECTION[SEND] & [3] + [TAP/RANGE]
CONNECTION[SEND] & [4] + [TAP/RANGE]
CONNECTION[SEND] & [6] + [TAP/RANGE]
[TAP/RANGE] + [SAMPLING]
[1] + [2] + [SAMPLING]
[SAMPLING] + [SAMPLE BANK C] + [SAMPLE BANK D]

Functions of switches

[TAP/RANGE]
[SAMPLE BANK A]
[SAMPLE BANK B]
[SAMPLE BANK C]
[SAMPLE BANK D]
[SAMPLE BANK A] + [TAP/RANGE]

Error Code

KP3 displays the Error Code in the LED, when an error occurred in the internal inspection.
4 digits of the LED indicates the error code.
[Er.**]
* (Ten's digit) : Item number (item of the internal inspection)
* (One's digit): Test number( In the internal inspection)
Item
1. DSP IF Check
2. DSP - SDRAM Check
3. CPU ROM Check
4. EEPROM Check
5. Loop Back Check (Audio)
6. MIDI Loop Check
7. Card Check
8. USB Check
*Initial Settings
Set the volumes and the switches like followings.
CONNECTION
INPUT Select
INPUTVR
Fx Depth
Slider
PHONES VR
MICTrim:MAX
SD Card (Protect OFF)
(Caution:) Use the AC Adaptor of KA-20*series

Internal Inspection

1. DSP IF Check
When an error occurred, the inspection stops displaying [Er.11]-[Er.13] in the LED display.
2. DSP SDRAM Check
When "Data Error", the inspection stops displaying [Er.22] or [Er.23] in the LED display.
When "Address Error", the inspection stops displaying [Er.21] in the LED display.
3. CPU ROM Check
When "Checksum Error", the inspection stops displaying [Er.31] in the LED display.
Notice: When the start-up condition or the forwarding between CPU <-> DSP is NG,
KP3 cannot start the test mode, because after the forwarding the Boot code,
KP3 moves to the self check sequence (TEST MODE).
*USB check needs a special computer, so skip by [SAMPLE BANK A] + [TAP/RANGE]
when an error occurred in the inspection.
: SEND
: LINE
: MAX
: MIN
: MIN (0)
: MAX
: MAX
: Skipping the Audio Loop Back Inspection and the USB check
: Skipping the MIDI Loop Back inspection and the USB check.
: Skipping the Audio Measurements and PAD surface inspection
: Audio Measurement only
: PAD all surface inspection only
: Full inspection (Internal and External)
: External inspection
: Display of System Version
: Load the Preset
: IPL Mode
: Step Up (When an error occurred in the internal inspection, retry the inspection.)
: Step + (Move within the item)
: Step - (Move within the item)
: Item Number Up
: Item Number Down
: When an error occurred in the internal inspection, skip the inspection
Connection for the automatic inspections
LINE OUT L
LINE OUT R
MIDI OUT
2006.8.30 KORG PD3 T.Kanai
English by M.Y.
Cable
LINE IN L
RCA cable
LINE IN R
RCA cable
MIDI IN
MIDI cable

Hide quick links: