Calibrating the Touch Pad

Depending on the operating environment, the touch pad segments that light when the
pad is pressed might be out of position. When this happens, the following steps should
be taken to re-calibrate the touch pad.
Please use a plastic pointing device such as a PDA stylus or a gaming device touch pen.
using a sharp or metallic object will risk damaging the touch pad surface.
1. Turn on the power while pressing the PROGRAM MEMORY 7, PROGRAM
MEMORY 8 and [SAMPLING] buttons.
"CAL.1" should appear on the display and the four bottom left touch pad segments
should light up.
2.
Using the pointing device, lightly touch the centre of the four lit segments where
the grid lines cross as shown in the diagram below.
!NOTE! do not move the pointing device from this position while the pad is touched.
After touching this point for a short while, the calibration will move onto the next
step: the next set of four segments will light and the display should read "CAL.2".
3. Remove the pointing device from the touch pad and repeat for the next position
indicated by the segment lights.
Complete all four steps as shown in the following diagrams.