Haier HTR13 Service Manual page 9

Haier model: 1407
Hide thumbs Also See for HTR13:
Table of Contents

Advertisement

5
Make C713/C714 open. Multimeter is at band RΧ1K. Red
probe connect to ground. Touch No.6 OR No.8 of IC701 with
No noise
Power amplifier is abnormal.
Inspect IC701 and peripheral
components of IC701
Yes
Inspect IC201 and peripheral
component of IC201
6.
Yes
Change V501 or
weld V501 again
Picture exists but no sound
Make C713 OR C714 collector
open. Touch No.6 OR No.8 of
Q702 with black probe to see if
Yes
Inspect C713、C714
Lack of red
Check to see if V501 is
open or not well welded
Check to see if voltages of SK501
No
Inspect
Inspect R502,R503,R504
Maintenance Service and Trouble shooting
Have noise
No
Check to see if
+16V exists
No
Inspect +16V
power supply
No
are normal
Inspect the circuit from
No.51 of IC201 to
No.3 of SK501
9
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents