STANDING PILOT IGNITION
SYMPTOM
6. Glass Soots
7. Flame burn blue and
lifts off burner (ghost-
ing)
37D0334
POSSIBLE CAUSE
A. Flame impingement on logs
A. Insufficient oxygen being
supplied
ACTION
A. Install log set per the instructions
Inspect the injector and air intake area. Make sure this area does
not have any blockage from debris and clean.
Check gas supply.
A. Ensure that the vent cap is installed properly and free of debris.
Ensure that the vent system joints are tight and have no leaks.
Ensure that no debris has been blocking the inner air intake at the
bottom back of the combustion chamber. Ensure that the glass is
properly secure and latch.
TROUBLESHOOTING