    Owner’s Guide Installation Instructions Gas Domestic Outdoor Water Heater 850 series 330, 360 models This water heater must be installed and serviced by a qualified person. Please leave this guide with the householder.
  • Page 2 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd.
  • Page 3: Table Of Contents

    CONTENTS HOUSEHOLDER – We recommend you read pages 4 to 20. The other pages are intended for the installer but may be of interest. About Your Water Heater ............4 Maintenance Requirements ............9 Water Supplies ................13 Save A Service Call ..............17 Installation ..................
  • Page 4: About Your Water Heater

    Its use in an application other than this may shorten its life. MODEL TYPE ® The Rheem water heater model you have chosen is suitable for outdoor installation only. The model is a high efficiency, quick recovery 850 series Stellar™...
  • Page 5 ABOUT YOUR WATER HEATER HOTTER WATER INCREASES THE RISK OF SCALD INJURY This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application and will not cause scald injury.
  • Page 6 Owner’s Guide and Installation Instructions. The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or if the installation is not in accordance with these instructions.
  • Page 7: About Your Water Heater

    ABOUT YOUR WATER HEATER MAINS PRESSURE The water heater is designed to operate at mains pressure by connecting directly to the mains water supply. If the mains supply pressure in your area exceeds that shown on page 23, a pressure limiting valve must be fitted. The supply pressure should be greater than 350 kPa for true mains pressure operation to be achieved.
  • Page 8 ABOUT YOUR WATER HEATER HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY? Installation requirements are shown on pages 28. The water heater must be installed:  by a qualified person, and  in accordance with the installation instructions, and ...
  • Page 9 Agent. Note: The service and routine replacement of any components, if required, are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater. The annual service includes the following actions: ...
  • Page 10 Note: The major service and routine replacement of any components, such as the anode and relief valve(s), are not included in the Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on this water heater.
  • Page 11 If water does not flow freely from the drain line when the lever is lifted, then the water heater should be checked by Rheem Service or their nearest Accredited Service Agent. The expansion control valve should be checked for performance or replaced at intervals not exceeding five (5) years, or more frequently in areas where there is a high incidence of water deposits.
  • Page 12: Maintenance Requirements

    If water does not flow freely from the drain line when the lever is lifted, then the water heater must be checked. Phone Rheem Service or their nearest Accredited Service Agent to arrange for an inspection. The temperature pressure relief valve should be replaced at intervals not exceeding 5 years, or more frequently in areas where there is a high incidence “Water Supplies”...
  • Page 13: Water Supplies

    Rheem warranty. In addition, the use of an incorrect colour coded anode may shorten the life of the water heater cylinder.
  • Page 14 WATER SUPPLIES TOTAL DISSOLVED SOLIDS (TDS) mg/L 2500 (CONDUCTIVITY - μS/cm) (60) (215) (570) (860) (3570) Green Black Blue Blue Above 2500 mg/L, Warranty applies to a vitreous-enamel-lined no warranty applies water heater cylinder if the correct coloured to a vitreous- enamel-lined water anode is used for the TDS of the water heater cylinder...
  • Page 15 Where the saturation index exceeds +0.40, the water is very scaling. An expansion control valve must be fitted on the cold water line after the non- return valve to protect and for the Rheem warranty to apply to the temperature pressure relief valve and water heater cylinder.
  • Page 16: Water Supplies

    Those chemistries are listed below. If the water heater is connected at any time to a water supply with the following water chemistry, the Rheem warranty will not cover any resultant faults on the components listed below: Water Chemistry Component Total Dissolved Solids (TDS) >...
  • Page 17: Save A Service Call

     Water heater size Do you have the correct size water heater for your requirements? The sizing guide in the Rheem sales literature and on the Rheem website (www.rheem.com.au) suggests average sizes that may be needed. WATER NOT HOT ENOUGH You may find that due to heavy hot water usage the water temperature may be lower than normally expected.
  • Page 18 The gas control must be turned off using the knob on top of the gas control “Close Down Procedure” thermostat (refer to on page 38). Phone Rheem Service or nearest Accredited Service Agent to arrange for inspection. EXPANSION CONTROL VALVE RUNNING...
  • Page 19 SAVE A SERVICE CALL CAN’T LIGHT THE PILOT FLAME  Is there gas to the water heater? Check the gas isolation valve on the gas supply line is open.  Is there a normal gas supply to the rest of the premises? Try lighting another gas appliance to check.
  • Page 20: Save A Service Call

     Has your water heating tariff rate been increased by your gas retailer since your previous bill? IF YOU HAVE CHECKED ALL THE FOREGOING AND STILL BELIEVE YOU NEED ASSISTANCE, PHONE RHEEM SERVICE OR THEIR NEAREST ACCREDITED SERVICE AGENT.
  • Page 21 INSTALLATION THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available (refer to the rating label on the water heater). INSTALLATION STANDARDS The water heater must be installed: ...
  • Page 22 INSTALLATION WATER HEATER LOCATION The water heater should be installed close to the most frequently used outlet and its position chosen with safety and service in mind. Make sure people (particularly children) will not touch the flue outlet. The flue terminal must be clear of obstructions and shrubbery.
  • Page 23 INSTALLATION The water heater must be located to ensure that the location of the flue terminal complies with the requirements of AS 5601 or AS/NZS 5601.1, as applicable under local regulations. As a guide the following requirements are extracted from the Gas Installations Standard. The distances are measured along the wall behind the water heater.
  • Page 24: Installation

    INSTALLATION TANK WATER SUPPLY If the water heater is supplied with water from a tank supply and a pressure pump system is not installed, then the bottom of the supply tank must be at least 1 m above the highest point of the hot water plumbing system, including the water heater.
  • Page 25 INSTALLATION HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between the water heater and the hot water outlets in any ablution and public areas such as a bathroom, ensuite or public amenities, to reduce the risk of scalding.
  • Page 26 INSTALLATION CIRCULATED HOT WATER FLOW AND RETURN SYSTEM If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used. Note: The thermostat must always be set to at least 60°C.
  • Page 27 Rheem warranty. In addition, the use of an incorrect colour coded anode may shorten the life of the water heater cylinder.
  • Page 28 INSTALLATION TYPICAL INSTALLATION – OUTDOOR LOCATION Installation Typical - Stellar Gas Domestic Water heaters Hourly Gas Min. Gas Test Point Gas Max. Gas Gas Details Consumption Pressure Pressure Pressure (MJ) (kPa) (kPa) (kPa) 330, 360 330, 360 330, 360 330, 360 Natural 1.13 1.00...
  • Page 29 INSTALLATION DIMENSIONS AND TECHNICAL DATA Dimensional Diagram Stellar 850 series 330 360 models Domestic Gas Outdoor Water Heaters Model 850 330 850 360 Storage capacity litres Hourly recovery litres (natural gas @ 45°C rise) First hour capacity litres Mass (tank) Empty Full Dimensions...
  • Page 30 CONNECTIONS – PLUMBING All plumbing work must be carried out by a qualified person and in compliance with the Standard AS/NZS 3500.4 and all local codes and regulatory authority requirements. All gas work must be carried out by a qualified person and in compliance with the Standard AS 5601 or AS/NZS 5601.1, as applicable under local regulations, and all local codes and regulatory authority requirements.
  • Page 31 CONNECTIONS – PLUMBING PIPE SIZES To achieve true mains pressure operation, the cold water line to the water heater should be the same size or bigger than the hot water line from the water heater. The pipe sizing for hot water supply systems should be carried out by persons competent to do so, choosing the most suitable pipe size for each individual application.
  • Page 32 CONNECTIONS – PLUMBING RELIEF VALVE DRAIN DN15 copper drain lines must be fitted to the temperature pressure relief valve and expansion control valve (if one is installed) to carry the discharge clear of the water heater. Connect the drain lines to the valves using disconnection unions.
  • Page 33: Connections – Plumbing

    Warning: Always isolate the water heater before pressure testing the gas supply system. Disconnect the water heater after the isolating cock to prevent the risk of serious damage to the gas control. The Rheem warranty does not cover damage of any nature resulting from failure to observe this precaution.
  • Page 34: Commissioning

    COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The gas pilot or burner must not be lit until the water heater is filled with water.  Open all of the hot water taps in the house (don’t forget the shower). ...
  • Page 35 COMMISSIONING TO TURN OFF THE WATER HEATER If it is necessary to turn off the water heater on completion of the installation, such as on a building site or where the premises is vacant, then:  Shut down the gas control (refer to “Close Down Procedure” on page 38). ...
  • Page 36: Lighting The Water Heater

    Turn the gas control knob clockwise to the “” (off) position, then turn off the isolation valve in the gas line to the water heater. Leave the area and call Rheem Service or a qualified service technician. Use only your hand to turn the gas control knob, never use tools. If the control knob will not turn by hand, call a qualified service technician.
  • Page 37 LIGHTING THE WATER HEATER LIGHTING INSTRUCTIONS Stop, read the safety information on page 36.  Remove the access cover. DANGER: If the main burner or pilot flame is extinguished for any reason during the lighting process, ALWAYS turn the gas control knob to the “”...
  • Page 38 Check the test point pressure and compare with the rating label. The pressure regulator is not adjustable and if the test point pressure is not within 5% of the specified value, refer to Rheem Service or their nearest Accredited Service Agent.
  • Page 39: Draining The Water Heater

    DRAINING THE WATER HEATER Warning: Exercise care, as water discharged from the water heater may be of a very high temperature. To drain the water heater:  “To Turn Off The Water Heater” Turn off the water heater (refer to page 35).
  • Page 40 This page is intentionally blank.
  • Page 41 This page is intentionally blank.
  • Page 42: Warranty

    2.1 The decision of whether to repair or replace a faulty component is at Rheem’s sole discretion. 2.2 If you require a call out and we find that the fault is not covered by the Rheem warranty, you are responsible for our standard call out charge. If you wish to have the relevant component repaired or replaced by Rheem, that service will be at your cost.
  • Page 43 3. WHAT IS COVERED BY THE RHEEM WARRANTY FOR THE WATER HEATERS DETAILED IN THIS DOCUMENT 3.1 Rheem will repair or replace a faulty component of your water heater if it fails to operate in accordance with its specifications as follows:...
  • Page 44 6.2 The Rheem warranty (set out above) is in addition to any rights and remedies that you may have under the Australian Consumer Law.