Install Drain Hose; Connect Wire Of Indoor Unit; Installation Of Indoor Unit - Toyotomi TRN/TRG-528ZR User Manual

Wall mounted air conditioner inverter type
Table of Contents

Advertisement

Available languages

Available languages

Installation of indoor unit

torque wrench
indoor pipe
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape.
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
2. Bind the joint with tape.
Note:
Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
The plastic expansion particles are
not provided.
Step seven: connect wire of indoor unit
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
Hex nut diameter Tightening torque (N . m)
open-end
wrench
9.52
union nut
pipe
drain hose
outlet pipe
tape
30
6
15~20
30~40
12
45~55
16
60~65
19
70~75
insulating pipe
outlet
pipe
drain hose
panel
wiring cover
drain hose
insulating pipe
screw