Test Switches; Test Frequency - Bunn SINGLE TF DBC Installation & Operating Manual

Hide thumbs Also See for SINGLE TF DBC:
Table of Contents

Advertisement

PROGRAMMING THE BREWER (cont.)
SERVICE TOOLS (cont.)
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to
be tested.
16. To test REFILL VALVE, press ON. If the refi ll valve
is functional, the sound of the valve operating will
be heard.
17. Press OFF to end testing of refi ll valve.
18. Press NEXT to advance to the next component to
be tested.
19. To test TANK HEATER, connect a voltmeter across
the tank heater to check for voltage.
20. Press ON. The correct voltage should be present
at the heater terminals.
21. Press OFF to end testing of the tank heater.
NOTE: The tank heater will automatically turn off if
left on too long.
22. After testing the tank heater, press NEXT to advance
to the next test.
23. The HEATER CONTACTOR is used only on certain
models. Check the machine schematic to see if the
contactor is present. Connect a voltmeter across
the tank heater and press ON to check that cor-
rect voltage is present. Press OFF and confi rm the
voltage is zero.
24. Press NEXT to return to TEST OUTPUTS.
25. To exit SERVICE TOOLS, press and release the
ON/OFF switch located on the front switch panel.
This will return to the MAIN SCREEN.
Procedure to test switches:
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1. Place brew funnel into rails on the brewer.
2. Place a server beneath the brew funnel.
3. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
SERVICE TOOLS.
4. Press YES to run tests on various components
and outputs within the brewer. (Pressing NO will
exit this function and advance to the next function
screen.)
5. The display should read TEST OUTPUTS.
6. In TEST OUTPUTS screen, press NO. This advances
to TEST SWITCHES.
7. Pressing NO in this screen will advance to the
next function. Press YES in the TEST SWITCHES
screen to test the switches. The display will read
NOTHING PRESSED.
8. From this screen, press any of the switches on the
front of the brewer. While the switch is pressed,
the display shows the name of that switch. If the
name does not appear, or if it remains after the
switch has been released, the switch is defective.
Each switch can be tested in this manner.
9. After all switches have been tested, press the up-
per right hidden switch located on the front switch
panel. This will exit TEST SWITCHES and return
to the MAIN SCREEN.
Procedures to test coil frequency:
1. Place brew funnel into rails of the brewer.
2. Place a server beneath the brew funnel.
3. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
SERVICE TOOLS.
4. Pressing NO will exit this function and advance to
the next function screen. Press YES to run tests
on various components and outputs within the
brewer.
5. The display should read TEST OUTPUTS.
6. In TEST OUTPUTS screen, press NO. Continue to
press and release NO until the display reads TEST
FREQUENCY.
7. Press and release YES. The display will show the
frequency of the sensor coil circuits. This is for
diagnostic service use when troubleshooting this
circuit.
8. After the coils have been tested, press and release
the ON/OFF switch located on the front switch panel.
This will exit the TEST FREQUENCY function and
return to the MAIN SCREEN.
NOTE: If the operator wishes to test more than one
function in the SERVICE TOOLS section (outputs,
switches, servers, or coil frequency), it is not
necessary to exit the program. Use the fl ow chart
for SERVICE TOOLS to navigate to a particular
function.
Page 38
35879.1 071405

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents