Machine Troubleshooting

PROBLEM
Poor or no water pick-up
Vacuum motor does not run, or
runs slowly
Poor scrubbing performance
Brush motors do not run, or
runs slowly
CAUSE
Squeegee out of adjustment
Debris caught on squeegee
Worn squeegee blades
Vacuum hose clogged
Vacuum hose disconnected from
squeegee or recovery tank
Vacuum hose damaged
Recovery tank not sealed
Foam filling recovery tank
Recovery tank full
Recovery tank float system dirty
Circuit breaker tripped
Loose connection
Faulty vacuum switch
Worn vacuum motor brushes
Debris caught in scrub brushes
Worn brushes or pads
Improper detergent, brush or pad used
Low scrub brush down pressure
Low battery charge
Circuit breaker(s) tripped
Loose connection
Faulty brush motor contactor
Worn brush motor brushes
86039070 CUTTER 24V
Maintenance
SOLUTION
Adjust squeegee
Remove debris
Rotate or replace squeegee blades
Clear obstruction from hose
Reconnect vacuum hose
Replace vacuum hose
Place recovery tank dome on tank.
Replace damaged gaskets.
Empty recovery tank
Use less or different detergent
Use defoamer
Drain recovery tank
Clean float system
Reset circuit breaker
Check motor wires and connections
Replace switch
Replace brushes, check commutator
Remove debris
Replace brushes or pads
Contact equipment or application
specialist
Increase brush pressure
Charge batteries
Reset circuit breaker(s)
Check motor wires and connection
Replace contactor
Replace brushes, check commutator
31