Installing Circulation Pumps - Central Boiler CL 4030 Owner's Manual

Outdoor wood furnace
Hide thumbs Also See for CL 4030:
Table of Contents

Advertisement

3-Pump Configuration (Taco 007 & Taco 014)
Fig. 12
3- Pump Parts List (Taco 007 & Taco 014)
Fig. 13

Installing Circulation Pumps

The following guidelines must be adhered to when
installing the circulation pump(s).
Section 1 - Furnace Installation
NOTE: See the Hydronic Component Selection
Guide (p/n 2482) for more information.
WARNING
Maximum load of the outlet on the outdoor
furnace is 10A, 120VAC, and 60Hz.
A. The pump motor must be installed in a horizontal
position.
B. The junction box must not be located below the
pump motor (see Fig. 14). If necessary, remove the
four screws and rotate the pump body.
Fig. 14
C. Do not operate the circulation pump until the entire
system has been filled with water and checked for
leaks or the pump will be damaged.
D. Insulate the areas around the supply and return lines,
pumps and drain valve (Fig. 15); then install and
secure the back panel.
Fig. 15
NOTE:Be sure to
insulate around the
pump(s) and water lines.
© 2007 Central Boiler
NOTE: If installing three pumps on the outdoor
furnace, use a UL approved adapter on the
receptacle outlet.
13