The fi replace and gas logs function as a system. If the fi replace is spilling into the room
(check with a match or a smoke stick), reposition the damper clamp until a positive
draft is obtained by opening the damper. If negative pressure in home prevents having
a positive draft, contact your dealer for assistance.
PLACING AND SECURING APPLIANCE
You must secure the gas log heater to the fi replace fl oor. If not, the entire unit may move
when you adjust the controls. Movement of unit may cause shifting of the gas logs which
leads to sooting and improper burning. Grate movement could cause a gas leak.
Special care is required if you are installing the unit into a sunken fi replace. You must
raise the fi replace fl oor to allow access to gas log controls. This will insure adequate air
fl ow and guard against sooting. Raise the fi replace fl oor using noncombustible materials,
as described in "Placement in a Fireplace with Restrictive Barrier" on page 11.
ASSEMBLY PROCEDURE:
1. Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the
fireplace or firebox.
2. Anchor holes are located on the right and left sides of the unit. After centering the grate correctly, mark the hole posi-
tions on the fireplace/firebox floor. Drill two (2)
3. Anchor the grate to the fireplace/firebox floor using the screws provided. See Figure 14.
Proper installation of the grate is essential to prevent any movement of the gas logs and controls during operation.
Screw
Anchor
Hole
44D0060
Figure 14 - Securing Heater to Floor of Fireplace/Firebox

INSTALLING VENTED APPLICATIONS

5
/
" diameter holes approximately 1
32
1
/
" deep.
2
Screw
Anchor
Hole