FIREPLACE FRAMING

Firebox framing can be built before or after the appliance is set in place. Construct firebox framing
following Figures 2 or 3 for your specific installation requirements. Refer to Figures 2 & 3 for firebox
dimensions. The framing headers may rest on the top of the firebox standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropri-
ate height. When the firebox is installed directly on carpeting, tile or other combustible material,
other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full
width and depth of the enclosure.
43 " (1102 mm)
Figure 2 -
BBV400 Fireplace
Dimensions and
Framing
Do not fill spaces around firebox with
insulation or other materials. This could
cause a fire.
6
Min. Rough 
Opening
Depth
14 "
(368 mm)
1/2" or 5/8" 
Drywall 
Spacers
9 "
(244 mm)
16 "
(426 mm)
7 "
(184 mm)
(56 mm)
FIREPLACE DIMENSIONS & FRAMING
31 " (797 mm)
1/2" or 5/8"
Drywall 
14"
Spacers
(356 mm)
40 " (1029 mm)
Min. Rough Opening Width
Min. Rough
Opening 
Height
40 "
(1029 mm)
36" (914 mm)
2
"
40" (1016 mm)
624037
400BBV dims
4" 
B-Vent
8"
(203 mm)
40"
(1016 mm)
34"
(864 mm)
21 "
(546 mm)
6"
(152 mm)
62D4036