Water Path Connections - Opening; Water Path Connections - Closing - Miele CVA615 Technical Information

Coffee system
Table of Contents

Advertisement

Technical Information
5.45

Water Path Connections - Opening

Danger!
Risk of burning or scalding!
Components may be hot.
Pressurized steam may exist in the system.
Before any service work is performed, allow time to cool.
Refer to Figure 5-51.
1. Remove the retaining spring (Item 1).
2. Pull out the hose from the connector.
3. Remove the sealing rings (Item 2).
1
2
3
Figure 5-51: Water path connection
5.46

Water Path Connections - Closing

1. Check the sealing rings for damage and replace as necessary.
2. Fit the sealing rings on the hose.
3. Insert the hose in the connector.
4. Fit the retaining spring behind the pressed-on ring.
5. As a check, pull on the hose. It should not be possible to pull the
hose out of the connector.
Retaining spring
Sealing rings
Pressed-on ring
92