8-3. Installation
8-3-1. Optional installation parts
Part
Code
Refrigerant piping
Liquid side : ∅6.35 mm
A
Gas side
Gas side
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
C
<Fixing bolt arrangement of outdoor unit>
RAS-10, 13 Series
115 mm
32.5 mm
Air outlet
600 mm
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
• Use ∅8 mm or ∅10 mm anchor bolts and nuts.
If it is necessary to drain the defrost water, attach 9 drain nipple and
bottom plate of the outdoor unit before installing it.
Parts name
: ∅9.52 mm (07, 10 series)
: ∅12.70 mm (13 series)
125 mm
Air inlet
90 mm
Drain outlet
Q'ty
One
each
1
One
each
RAS-07 Series
Fig. 8-3-1