Ras-10Ukp-Es3 / Ras-10Ua-Es3; Ras-10Ukp-As3 / Ras-10Ua-As3 - Toshiba RAS-13UKHP-ES3 Service Manual

Hide thumbs Also See for RAS-13UKHP-ES3:
Table of Contents

Advertisement

5-4. RAS-10UKP-ES3 / RAS-10UA-ES3

RAS-10UKP-AS3 / RAS-10UA-AS3

Cooling
0.39m
(Connecting pipe)
∅9.52
P
O.D.:9.52mm
Packed valve
(∅9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Evaporator
Cross flow fan
PA108X1T-4FZ1
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (°C)
0.95
1.15
0.85
− 20 −
FILE NO. SVM-04001
T1
Packed valve
(∅6.35)
Capillary tube
∅1.5x1100l
Refrigerant
R410A : 0.65 kg.
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
11.0
High
15.0
High
5.0
Low
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15