Troubleshooting - U-Line 95 Icemaker Service And Parts Manual

Table of Contents

Advertisement

NEVER attempt to repair or perform maintenance on the unit until the main
electrical power has been disconnected.
1. Will not eject ice (water frozen)
Cause
Control setting too cold
Control defective (1-2 contacts open)
Bin switch defective
Limit switch defective (open)
Ice maker assembly motor stalled
Broken wire in ice maker circuit
Water soaked cabinet insulation
Dirty condenser
2. Will not fill with water
Cause
Water supply valve closed
Water switch defective (open)
Solenoid valve defective
Fill tube outlet frozen
Broken wire in water fill circuit
3. Will not stop making ice
Cause
Bin switch defective (closed)
Bin arm binding
4. Water will not stop filling
Cause
Water switch defective (closed)
Solenoid valve defective
Stalled ice maker motor
Temperature control defective.
Ice maker is in continuous harvest
cycle (contacts 1-2 closed)
5. Ejector blades will not stop turning
Cause
Control defective (1-2 contacts will
not open)
Hold switch defective
Defective wiring
Short in mold heater

TROUBLESHOOTING

!
Replace bin switch
Clean condenser
Remedy
Remedy
Lubricate bin arm pivot points or loosen
bin arm lever screw
Remedy
Remedy
Repair or replace wiring
Replace heater
!
Remedy
Adjust control warmer (counterclockwise)
Replace control
Replace limit switch
Replace motor
Repair or replace wiring
Replace foamed cabinet assembly
Open water supply valve
Replace water switch
Replace solenoid valve
Replace solenoid valve and defrost fill tube
Repair or replace wiring
Replace bin switch
Replace water switch
Replace solenoid valve
Replace motor
Replace temperature control
Replace control
Replace hold switch