Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Reset position detection error on the stepper
E
6
1
3
0
iris initializing
Handshake correction function does not work
E
6
2
0
0
well. (With PITCH angular velocity sensor
output stopped.)
Handshake correction function does not work
E
6
2
0
1
well. (With YAW angular velocity sensor
output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller com-
E
6
2
0
3
munication abnormality among.
I m a g e v i b r a t i o n c o r r e c t i o n d u r i n g
E
6
2
0
4
handshake function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
9
1
0
1
Abnormality when flash is beingcharged.
E
9
1
0
2
*
Abnormality of LED Video light.
Abnormality of LED Video light Tempera-
E
9
1
0
3
*
ture detection.
Battery current value goes over the max
*
E
9
2
0
1
discharge current
Fault of writing or erasing the flash mem-
E
9
4
0
0
ory
E
9
4
0
1
Internal flash memory fault
E
9
4
0
2
BGM data error
HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
Correction
Inspect the lens block zoom sensor signal (pin 5 of CN1001 on the
VC-657 board) when zooming is performed when the zoom lever is
operated, and the zoom motor drive circuit (IC5501 on the VC-657
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens
drive block (CN1001 pin qf, qg on VC-657 board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens block).
・ Case of "E: 61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
tween CN7502 on CM-128 board and CN1004 on VC-657 board
by FP-1524 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
Inspect PITCH angular velocity sensors (SE7501 on the CM-128
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7501 on the CM-128 board)
peripheral circuits.
Refer to [1-11-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
Inspect the steadyshot circuit (IC5501 on the VC-657 board).
Inspect the image vibration angular velocity sensors (SE7701 on the
VC-657 board) peripheral circuits.
Replacement of lens block. (Note 3) If an error occurs again, replace
the VC-657 board.
Refer to [1-11-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
Refer to [1-11-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
Refer to [1-11-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
Check or replace the flash or charging capacitor.
Turn power off and turn power on again.
Turn power off and turn power on again.
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed.
Inspect the flash memory (IC8101 on the VC-657 board).
Inspect the flash memory (IC8101 on the VC-657 board).
Check the CPU (IC1301 on the VC-657 board).
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
E
9
5
0
0
GPS hardware error
E
9
6
0
0
Map area mount error
E
9
7
0
0
Projector hardware error
*
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.

1-11. METHOD OF COPING WITH SHIFT LENS ERROR

VC-657 BOARD (SIDE A)
Measurement points on the VC-657 board
1-11
– ENGLISH –
Correction
GW55VE/GW77V/GW77VE:
Check whether the FP-1530 flexible board is broken,and check
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of
the GP-055 board.
GW55VE/GW77V/GW77VE:
Inspect or replacement of the VC-657 board.
Turn power off and turn power on again.
IC5501
C5528
Fig. 1

Hide quick links: