Connector
Pin
YC8
1
+3.3V
Connected to
2
GND
scanner
3
TIMSWN
PWB
4
ORGSWN
5
OPSWN
6
DPDETN
7
RELSOLN
8
PRESOLN
9
REVSOL
10
FEEDCL
Signal
I/O
I
3.3 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
I
0/24 V DC
Voltage
3.3 V DC power from MPWB
Ground
DPTS: On/Off
DPOS: On/Off
DPOCS: On/Off
DP set signal
DPPRSOL: On (Release)/Off
DPPRSOL: ON (Press)/Off
DPSBSOL: On/Off
DPPFCL: On/Off